Inputs - Datalogic DS2100N Reference Manual

Hide thumbs Also See for DS2100N:
Table of Contents

Advertisement

5

5.5 INPUTS

There are two optocoupled polarity insensitive inputs available on the scanner: Input 1
(External Trigger) and Input 2, a generic input:
The electrical features of both inputs are:
Maximum voltage:
Maximum current:
An anti-disturbance filter is implemented in software on both inputs so that the minimum
pulse duration is ≅ 5 milliseconds. This value can be increased through the software
parameter Debounce Filter, see the "2K/4K Family Software Configuration Parameter Guide"
Help file".
25-pin
Name
9
Vdc
18
I1A
19
I1B
7
GND
The External Trigger input is used in the On-Line operating Mode and tells the scanner to
scan for a code. The active state of this input is selected in software. Refer to the Genius™
Help On Line.
The yellow Trigger LED
corresponds to ON.
This input is optocoupled and can be driven by both an NPN and PNP type command. The
connections are indicated in the following diagrams:
Figure 56 - PH-1 Photocell (PNP) External Trigger Using DS2100N Power
60
30 Vdc
12 mA
Function
Power Source - External Trigger
External Trigger A (polarity insensitive)
External Trigger B (polarity insensitive)
Power Reference - External Trigger
(Figure
A, 3) is on when the active state of the External Trigger
EXTERNAL TRIGGER INPUT PNP PH-1
DS2100N
9
Vdc
I1A
18
V
~
CC
-
I1B
+
19
~
7
GND
DS2100N REFERENCE MANUAL
PNP PH-1 wires
(brown) +10-30 Vdc
(black) NO
(blue) 0 V

Advertisement