Datalogic DS2100N Reference Manual page 12

Hide thumbs Also See for DS2100N:
Table of Contents

Advertisement

1
CBX100/500 Pinout for DS2100N
The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the DS2100N reader is connected by means of the CBX100/500:
Input Power
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
+V
Power Source – External Trigger
I1A
External Trigger A
I1B
External Trigger B
-V
Power Reference – External Trigger
+V
Power Source – Inputs
I2A
Input 2 A
I2B
Input 2 B
-V
Power Reference – Inputs
Shield
Network Cable Shield
RS232
* Do not leave floating, see par. 4.2.2 for connection details.
Do not connect GND, SGND and REF to different (external) ground
references. GND, SGND and REF are internally connected through filtering
circuitry which can be permanently damaged if subjected to voltage drops
CAUTION
over 0.8 Vdc.
2
CBX100/500 Terminal Block Connectors
Inputs
(polarity insensitive)
(polarity insensitive)
(polarity insensitive)
(polarity insensitive)
Shield
Main Interface
TX
RTS
RX
CTS
SGND
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
REF
Network Reference
ID+
ID-NET™ network +
ID-
ID-NET™ network -
RS485 Full-Duplex
TX+
TX-
*RX+
*RX-
SGND
DS2100N REFERENCE MANUAL
Outputs
ID-NET™
RS485 Half-Duplex
RTX+
RTX-
SGND

Advertisement

Table of Contents
loading

Table of Contents