General Fault Messages; E02 Overcurrent; E04 Pump Rotor Blocked; E07 Test Alert - KSB CalioTherm Pro 25 Installation & Operating Manual

Circulator / high-efficiency drinking water pump
Table of Contents

Advertisement

Table 35: Error codes, causes and response
Error code on the dis-
Cause
play
E01
Excessive temperature
E02
Overcurrent
E03
Internal fault
E04
Pump rotor blocked
E05
Temperature limit reached
E06
Voltage error
E07
Test alert
E08
Motor fault
E09
High fluid temperature
E11
Broken wire of temperature sensor (NTC
thermistor) in the motor
E12
Firmware update required
E13
No pump model stored
E15
Minimum flow
E16
Maximum flow
E17
Externally forced flow
I10
Broken wire at analog input
I14
For dual pumps both pumps are pro-
grammed as "left pump".
I18
Externally forced flow in pumping direc-
tion
I19
Backflow through the pump
7
Further information in the KSB ServiceTool supplementary operating manual (reference number 1157.801)
60 of 76
7 Operation

7.3.10 General fault messages

7)
CalioTherm Pro
Status
Response
Alert
Pump stops.
Alert
Pump stops.
Alert
Pump stops.
Alert
Pump stops.
Warning
Speed is reduced.
Alert
Pump stops.
Alert
-
Alert
Pump stops.
Warning
-
Warning
Speed is reduced.
Alert
Pump stops.
Alert
Pump stops.
Warning
-
Warning
-
Alert
Pump stops.
Information The pump behaviour can be set
via the
KSB ServiceTool.
Information Pumps keep running.
Information Pump keeps running.
Information Pump keeps running.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Caliotherm pro 80

Table of Contents