6 Commissioning/Start-up/Shutdown

6.2.4 Maximum operating pressure

CAUTION
Permissible operating pressure exceeded
Damage to connections and seals!
▷ Never exceed the operating pressure specified in the data sheet.
The maximum operating pressure equals 6 or 10 bar, depending on the design
variant. See name plate. (ð Section 4.4, Page 15)

6.2.5 Fluid handled

6.2.5.1 Permissible fluids to be handled
CAUTION
Using the equipment for heating applications
Damage to the pump (set)!
▷ Never use a drinking water pump for heating applications.
CAUTION
Unsuitable fluids
Damage to the pump!
▷ Never use the pump to handle corrosive, combustible or explosive fluids.
▷ Never use the pump to handle waste water or abrasive fluids.
▷ Do not use the pump for foodstuff applications.
▪ Drinking water and water for the food and beverage industry, as per German
TrinkwV 2001 drinking water regulations
6.2.5.2 Density of the fluid handled
CAUTION
Impermissibly high density of the fluid handled
Motor overload!
▷ Observe the information on fluid density in the data sheet.
The power input of the pump set will change in proportion to the density of the fluid
handled.