Battery
- Check condition
The batteries are sealed and maintenance-free.
The cable shoes should be clean and tightened.
Corroded cable shoes should be cleaned and greased
with acid-proof Vaseline.
Wipe the top of the battery.
Air conditioning (Optional)
- Inspection
Inspect refrigerant hoses and connections and make
sure that there are no signs of an oil film that can
indicate a refrigerant leakage.
The refrigerant contains tracing liquid, which makes it
possible to detect leaks with the aid of a UV lamp. If
the areas around the connections are strongly
coloured, this is an indication of a leak.
1
4812159001_I.pdf
Maintenance measures - 250 h
Make sure there is no open flame in the vicinity
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
is formed when the alternator charges the battery.
When disconnecting the battery, always
When disconnecting the battery, always
disconnect the negative cable first. When
disconnect the negative cable first. When
connecting the battery, always connect the
connecting the battery, always connect the
positive cable first.