The Display Shows The Following Message: "An Error Has Occurred, Switch The Equipment Off And On Again; The Display Shows "Press A Keys / Touch The Screen - Technogym RUN PERSONAL Technical Service Manual

Hide thumbs Also See for RUN PERSONAL:
Table of Contents

Advertisement

6.8. THE DISPLAY SHOWS THE FOLLOWING MESSAGE: "AN
ERROR HAS OCCURRED, SWITCH THE EQUIPMENT OFF
AND ON AGAIN"
This message appears when a communication error occurs between the HK and the
LK.
The message on the Display: "AN ERROR HAS OCCURRED, SWITCH THE EQUIPMENT OFF
AND ON AGAIN" tells the user to reset the equipment if the error can be resolved by switching the
equipment OFF and ON again, thus avoiding intervention of technical service for simple operations
that can be solved by the user.
After three consecutive communication errors between the HK and LK, the equipment will
automatically display the following message on the screen: "EQUIPMENT BLOCKED (COM)".
Take action as described below, in paragraph: 6.12. "The display shows the following message:
"Equipment blocked (COM) CONTACT TECHNICAL SERVICE" "
6.9. THE DISPLAY SHOWS "PRESS A KEYS / TOUCH THE
SCREEN"
This error message can be caused by:
• loss of communication between the lower and upper assemblies;
• the user has pressed the emergency button;
• defective emergency button: the micro switch is opened.
In order to reinstate normal operation, simply press any key. If communication between the upper
and lower assemblies is not immediately re-established, the message will remain on the display
while the machine continues trying for 30 seconds, after which the "THE EQUIPMENT IS
BLOCKED" message will appear.
The machine keeps count of the attempts to reinstate communication by incrementing the
COM.FAULT parameter, which can be viewed using the procedure described in the relevant
paragraph of the Service menu.