Hr (Heart Rate) Signal; Hs/Hr (Hand Sensor) Receiver - Technogym RUN PERSONAL Technical Service Manual

Hide thumbs Also See for RUN PERSONAL:
Table of Contents

Advertisement

RUN PERSONAL + UNITY: Service & maintenance manual - rev. 4.1
6.16. NO HR (HEART RATE) SIGNAL
HUMAN BODY "CONTINUITY": It is statistically recognised that for some people it
is difficult (if not impossible) to measure their HR by Hand Sensors. This may be due
to numerous causes which are able to alter the continuity of the "electrical" contact
between the user's skin and the HS electrodes, such as: hands only just washed or
particularly dry, acidity of the skin and/or a particular body fat mass index. For these
people it's suggested to wear the chest belt.
CORRECT HAND SENSOR USE: Grasp both the upper and lower plate avoiding
clenching them too hardly. Avoid washing the hands using soaps that can dry the skin
too much.
6.16.1. HS/HR (H
Description of
the problem
There is no HR
signal
S
) R
AND
ENSOR
ECEIVER
Possible cause:
Display Board not
updated/not
programmed correctly
Display Board not
powered
Receiver Board not
powered or defective
The HS plates are
defective
The Driver does not
supply power
Components
involved:
Display Board
Receiver Board
Connector cables
HS plates
Driver
What to do:
Check the
Display Board SW and
the earthing of the
Receiver Board.
Check the voltages input
to the Display Board.
Reconnect and/or
replace
Check that there is NO
continuity between the
HS plates and the earth
on the Cardio Receiver
(to prevent discharges
to earth).
Replace.
Check the voltages
output to the Driver.
Page 6.13