6.4. "THE EQUIPMENT IS BLOCKED" MESSAGE ON THE
DISPLAY
This error message can be caused by:
• loss of communication between the lower and upper assemblies;
• the AT driver has detected an error condition, causing it to generate an alarm and store the error
code in memory.
• problem on the emergency button.
To optimize the troubleshooting procedure, follow the steps below:
1. Access the item "TROUBLESHOOTING AUTOMATIC TEST
TEST Low Kit COM Test". If the outcome of the test is negative, check the components of
the link between the upper and lower kit, in particular:
• check that the wiring of the cable (CU133) is not damaged, in particular the cables of the
"emergency signal" and of the "reset" by referring to paragraph 2.7. "Wiring", using the
Test Box Excite.
• try replacing each of the circuit boards in turn (display board or AT driver board) and check
whether the communication works.
If the outcome of the test is OK move on to step 2.
2. Access the item "TROUBLESHOOTING AUTOMATIC TEST Inverter Test". If the
outcome of the test is negative, check the error code stored in the "ERRORS LOG" and
perform the corresponding troubleshooting procedure, if the outcome is OK advance to step 3.
3. The machine lockout problem has to do with the handling of the emergency signal:
• check that the emergency button is not pressed;
• check that the cord, linked to the emergency button, is not to taut so that it keep the
emergency button contact open;
• check that all the cables linked to the emergency device management are properly connected
and in a good state of wear.
WARNING: if the display board detects an error condition during the tread belt motor
movement, it displays the error message and turns off the AC motor by the AT driver.
Page 6.10
JOG EXCITE: Service & Maintenance Manual - rev. 1.1
SERIAL PORTS
Need help?
Do you have a question about the JOG EXCITE and is the answer not in the manual?