Inspect Coolant Hoses (Lp, Dual Fuel Engine Only); Lp Regulator/Converter Inspection (Lp, Dual Fuel Engine Only); Fuel Lines & Fittings - Check - Doosan D35C-5 FDA04 Operation & Maintenance Manual

Table of Contents

Advertisement

Inspect Coolant Hoses (LP, Dual
Fuel Engine Only)
1. Visually inspect coolant hoses and clamps.
Remember to check the two coolant lines that
connect to the pressure regulator/converter.
2. Replace any hoses that shows signs of swelling,
cracking, abrasion or deterioration.
G424I(E) Engine Only
1
G430FE/G424P(E) Engine Only
1
(1) LP Regulator/Converter
(2) Coolant hoses
LP Regulator/Converter Inspection
(LP, Dual Fuel Engine Only)
1. Visually inspect the pressure regulator /
NOTE: For pressure testing and internal inspection
2
Fuel Lines & Fittings - Check
Visually inspect fuel lines and fittings for physical
damage. Replace as required.
G424I(E) Engine Only
2
G430FE/G424P(E) Engine Only
(1) Fuel lines
(2) LP mixer
(3) Throttle Assembly
-239-
converter housing for coolant leaks and detect
the
fuel
pipe
joints,
regulator/converter for LP fuel leaks.
To detect the LP fuel leaks, smear detected
parts with suds, visually inspect whether there
are bubbles after the engine start.
of the pressure regulator/converter, contact
to the Doosan service.
1
3
1
Maintenance Section
LP
mixer
and
2
2
3

Hide quick links: