Doosan D35C-5 FDA04 Operation & Maintenance Manual page 88

Table of Contents

Advertisement

Operation Section
Changing LP Tanks
WARNING
Only trained, authorized personnel should fill or
exchange LP tanks.
Personnel engaged in filling of LP containers
should wear protective clothing such as face
shield, long sleeves and gauntlet gloves.
Do not refuel or store LP powered lift trucks
near any underground entrance, elevator shafts
or any other place where LP could collect in a
pocket
causing
a
condition.
Examine all LP containers before filling and
again before reuse, for damage to various
valves, liquid gauge, fittings and hand valve
wheels.
All defective or damaged LP containers must be
removed from service.
Explosive fumes
may
refueling.
Do not smoke in refueling areas.
Lift truck should be refueled only at designated
safe locations. Safe outdoor locations are
preferable to indoor locations.
Stop the engine and get off the lift truck during
refueling.
The careless handling of LP containers can
result in a serious accident.
Use extreme care when transporting containers
to prevent damage to them.
1. Park the lift truck on level ground, with the
parking brake applied, the transmission in
NEUTRAL, the forks lowered and the engine
running at low idle.
potentially
dangerous
be present
during
2. Close the fuel shut off valve at the LP tank. Run
the engine until it stops, then turn off the ignition
switch and the disconnect switch (if equipped).
3. Disconnect the fuel supply line.
If Swing out type LP-Cradle Equipped
4. Loosen the retaining clamps and remove the
tank.
5. Check the mounting to be sure the locating pin
(dowel) is not missing or broken.
-86-

Hide quick links:

Advertisement

Table of Contents
loading