Doosan D35C-5 FDA04 Operation & Maintenance Manual page 112

Table of Contents

Advertisement

Operation Section
Problem
Will Not
Accelerate/Hesita
tion During
Acceleration or
Engine Stalls
(Gas)
Rough Idle (Gas)
Probable Cause
Throttle butterfly valve not opening
or sticking
Foot Pedal signal incorrect or
intermittent
Incorrect air/fuel or ignition control
Engine Mechanical
Isolate the gasoline system by
running the lift truck on LPG
Pressure regulator malfunction
Clogged fuel filter
Pressure regulator malfunction
Fuel Injector malfunction
Vacuum leak
See Advanced Diagnostics
See Engine Service Manual
Verify LPG cylinder is full and valve is open.
If the problem does not exist in LPG mode
proceed with the corrective action steps
below.
If the problem also exists in LPG mode then
the root cause is most likely to be
something other than the fuel system
See Advanced Diagnostics & Service
Manual
Test pressure regulator operation
See Engine Service Manual
Repair/replace as required
See Maintenance section, Primary and
Secondary Fuel Filter replacement
Test pressure regulator operation
See Engine Service Manual
Test Injector operation
See Engine Service Manual
Check for vacuum leaks
Between mixer and throttle body
Between throttle body and intake
manifold
Between intake manifold and cylinder
head
-110-