Basic Troubleshooting (Gasoline)
Problem
Engine Cranking
but Will Not Start
(Gas)
Probable Cause
Fuel tank empty
Clogged fuel filter
Faulty vapor connection between
the pressure regulator/ converter
and the mixer (LPG)
Electric Fuel Pump malfunction
(GAS)
Fuel Pressure regulator malfunction
Fuel Injector malfunction
Incorrect air/fuel or ignition/ spark
control
No VR Sensor Signal
Fill fuel container
The tank should be at least ¼ full to
properly prime the fuel pump.
Fuel select switch is not on GAS
Repair/replace as required
See Maintenance section Primary and
Secondary Fuel Filter replacement
Check connection
Verify no holes in hose
Clamps must be tight
Look for kinked, pinched and/or
collapsed hose
Check electrical connection
Check Relay and fuse
Turn key ON and verify pump is operating
Test pressure regulator operation
See Engine Service Manual
Test Injector operation
See Engine Service Manual
See Advanced Diagnostics
Verify the VR signal is present
See Advanced Diagnostics
-107-
Operation Section
Corrective Action