Common Faqs; Behaviour Of The Battery Leds - Salicru EQUINOX EQX2 3001-HSX User Manual

Single-phase hybrid solar inverters connected to the grid
Table of Contents

Advertisement

Available languages

Available languages

Questions
1
What is the
maximum charge
and discharge
power of the
battery?
2
What is the
maximum Back-up
Load power?
3
What is the
maximum
generation power?
4
What happens if
the battery reaches
the minimum SOC
(maximum DOD)?
5
Why does the hybrid
remain in standby
state despite having
the charge and
discharge profiles
configured?
6
What happens if
the grid is lost?
Tab. 10. Economy mode FAQs.

4.5.5. Common FAQs.

Questions
1
What happens if the battery is
discharged completely?
2
Why does the battery
discharge at maximum power
by injecting its energy into the
grid even when exporting is
disabled?
3
Why is the work mode not
changing?
4
Why will it not connect to
the WiFi?
5
Why is it not recognising the
battery/why are the hybrid
unit's SOC LEDs switched off?
6
Correct procedure for starting
the hybrid inverter with
SALICRU batteries
68
Answers
The maximum charge and discharge power of the
battery is the inverter's maximum PAC.
The maximum Back-up Load power is 110% of the
rated power of the inverter
The maximum generation power is PAC
The battery remains in standby mode and is only
charged if charge mode is enabled. The loads are
supplied in parallel to the battery charge from the
grid.
The hybrid's clock may be incorrect and it may think
it does not have any profiles enabled within the set
time range. The best is for the charge and discharge
profiles to cover 24 hours.
First of all, you can only use the back-up load.
The charge profiles stop supplying the back-up load
with solar panel surpluses, but they do continue to
charge the battery. The Standby profile stops working,
as this mode behaves like any inverter without
batteries that does not generate power when the grid
is lost. The discharge profile continues to operate and
supplies the back-up loads.
Answers
The battery enters a state where it is only
charged at 0.8 kW of power until it reaches
the min. SOC; in this state the Back-up Load
cannot be supplied.
The CT transformer may be wired
incorrectly. The correct orientation is
Load -> Grid.
The grid may not be available at the
moment and changing the work mode
requires the grid to be available
To connect to the WiFi, you need to have
2.4 GHz WiFi and a lower-case SSID.
The battery type may not be configured
correctly in the hybrid unit.
1. Activate the DC switch.
2. Activate the battery's circuit breaker.
3. Press the battery button for 5 seconds
4. Activate the AC switch.
Questions
7
Correct procedure for
1. Disconnect the AC and load switches
switching off the hybrid
2. Press the battery button for 5 seconds
inverter with SALICRU
3. Deactivate the battery's circuit breaker.
batteries.
4. Wait 30 seconds and deactivate the
inverter's DC switch.
5. Wait 5 minutes until the inverter
is completely de-energised before
disconnecting the AC and DC cables.
8
Procedure to change the
1. Press the button once to turn on the LED
communication mode
display.
(Wi-Fi or bluetooth).
2. Press and hold for 5 seconds until the
"Module Work Mode" menu appears.
3. Press for 3 seconds to enter the menu
and change to "ESP-Wifi" for WiFi
communication or "ESP-BLE" for bluetooth
communication.
9
Why does the SALICRU
The battery can be reconnected if the
battery button LED remain on
inverter is on and thus the LED remains on.
despite having held the button
Therefore, for correct shutdown, the circuit
down for 5 seconds?
breaker must also be disconnected.
10
Why does the SALICRU
When disconnecting the circuit breaker,
battery button LED remain
the battery output with the inverter is
on despite having turned the
disconnected, but if the inverter is on, it can
circuit breaker off?
reconnect the battery and therefore the LED
on the button.
Tab. 11. Common FAQs.

4.5.6. Behaviour of the battery LEDs.

LED status
Battery
status
Status LED Button LED
Yellow
Green
Checking
Green
Green
Charging
Flashing
Green
Discharging
green
Off
Off
Off
Quick
N/A
flashing
Turning off
green
Flashing
Off but
Off
green
charging
Tab. 12. LED behaviour.
Answers
Do not turn off the battery system
while the inverter is generating.
Description
Battery charging
Battery discharging
Battery off
Battery turning off. Occurs when
the battery button is pressed for
5 seconds
Occurs when the battery is turned
off using the button and the circuit
breaker is not deactivated. Battery
stays on with charging option.
SALICRU