System Operation; Description Of The Screens - Salicru EQUINOX EQX2 3001-HSX User Manual

Single-phase hybrid solar inverters connected to the grid
Table of Contents

Advertisement

Available languages

Available languages

7. SYSTEM OPERATION.

7.1. DESCRIPTION OF THE SCREENS.

When the inverter is started, the following interfaces will be
displayed on the OLED screen, which allows the user to check
different types of operating information, as well as to change the
inverter settings. Please refer to the following screen operation
flow chart for more details:
"V-Ipv1/2" screen menu.
1.
Screen 1.1
Screen X.X Indicator of the voltage and current of
the solar field connected to MPPTs 1 and 2.
"V grid" screen menu.
2.
Screen 2.1
Indicator of the grid voltage.
"I grid" screen menu.
3.
Screen 3.1
Indicator of the current supplied to the installation.
"F grid" screen menu.
4.
Screen 4.1
Indicator of the grid frequency.
"E. Day Analys." screen menu.
5.
Screen 5.1
Indicator of the energy generated during the day.
"E. Tot. Analys." screen menu.
6.
Screen 6.1
Indicator of the energy that has been generated
since the start-up of the inverter.
"Time ON" screen menu.
7.
Screen 7.1
Indicator of the time that the inverter has been in
operation since its start-up.
"General Settings" screen menu.
8.
Screen 8.1
Main screen of the "General Settings" menu.
Screen 8.2
"Info.System" Inverter information.
Screen 8.2.1 Firmware version of the device.
Continued 8.2.3.
Screen 8.2.2 SSID. Identifying the WiFi network.
Screen 8.2.3 FW version (II).
Screen 8.3
Fault Info.
Screen 8.4
RSSI. Indicator of the intensity of the WiFi signal
received (Received Signal Strength Indicator).
Screen 8.5
Rest. WiFi. Reset the WiFi settings.
Screen 8.6
Upd. WiFi. Update the unit via WiFi.
Screen 8.7
Safety UNE 217002.
Screen 8.7.1 EN50549.
Screen 8.7.2 Vietnam.
Screen 8.7.3 IEC (50 Hz).
Screen 8.7.4 IEC (60 Hz).
Screen 8.7.5 India.
Screen 8.7.6 Philippines.
Screen 8.7.7 Sri Lanka.
Screen 8.7.8 Italy.
82
Screen 8.7.9 EN50549(Cz).
Screen 8.7.10 EN50549(Tr).
Screen 8.7.11 EN50549(Ie).
Screen 8.7.12 EN50549(Se).
Screen 8.7.13 EN50549(Hr).
Screen 8.7.14 South Africa.
Screen 8.7.15 G99.
Screen 8.7.16 50 Hz default.
Screen 8.7.17 60 Hz default.
Screen 8.7.18 VDE4105.
Screen 8.8
Adj. Work. Mode. Configuration of the hybrid
inverter's work mode.
8.9
Screen
Batt. Ident. Battery manufacturer configuration
Screen 8.10 P.
Limit
ON/OFF.
power.
Screen 8.11
Export. Percentage injected into the grid. 0% for
zero injection and 100% to dump surpluses into the grid.
Screen 8.12
Pow. factor. Power factor.
Screen 8.13
CT ratio. Transformation ratio of the current
transformer (CT).
Screen 8.14
Modbus Addr.
Screen 8.15
Date/Time.
Screen 8.16
Language.
Screen 8.16.0 Spanish Language.
Screen 8.16.1 Polish language.
Screen 8.16.2 Czech Language.
Screen 8.16.3 English Language.
"Advanced Settings" screen menu.
9.
Password "1111".
Screen 9.1
Grid Isolating Switch. If enabled, the inverter will
automatically switch to off-grid mode to ensure back-up loads
when the grid is abnormal or off.
Screen 9.2
Grid Disconn. If it is enabled, it reduces the
switching sensitivity of On/Off-Grid if the grid is unstable.
Screen 9.3
Reconnection T. Reconnection time when there is
no grid and there is an overload in the back-up line.
Screen 9.4
NON-PEAK mode. Function to enable the non-
peak consumption option.
Screen 9.5
Grid Pmax kVA. Power limit for non-peaks.
Screen 9.6
Pr. SOC On-Gr. Function to enable the SOC protec-
tion for the On-Grid battery.
Screen 9.7
On-Grid DOD. Configuration of the On-Grid protec-
tion DOD.
Screen 9.8
Pr. SOC Off-Gr. Function to enable the SOC protec-
tion for the Off-Grid battery.
Function to limit the inverter
SALICRU

Advertisement

Chapters

Table of Contents
loading

Table of Contents