4 - Front Panel Operation

10 - Setting the GPIB Address and RS-232 Parameters

Your ac source is shipped with the GPIB address set to 5 This address can only be changed from the front
panel using the Address menu located under the
GPIB or RS-232 interface, and specify RS-232 parameters such baud rate and parity.
Action
To set the GPIB address, proceed as follows:
1.
On the System keypad, press Address.
2.
Enter the new address. For example, Press 7, Enter.
To configure the RS-232 interface, proceed as follows:
1.
On the System keypad, press Address.
Scroll through the Address menu by pressing  . The interface command
2.
lets you select either the GPIB or the RS-232 interface. The baudrate
command selects the baudrate. The parity command selects the parity.
The  and  keys let you select the command parameters.
3.

11 - Saving and Recalling Operating States

You can save up to 16 states (from location 0 to location 15) in non-volatile memory and recall them
from the front panel. All programmable settings are saved. List data, however, cannot be saved in state
storage. Only one list is saved in non-volatile memory.
Action
To save an operating state in location 1, proceed as follows:
1.
Set the instrument to the operating state that you want to save.
Save this state to location 1. Press Shift Save 1 Enter.
2.
To recall a saved state in location 1, proceed as follows:
1.
Recall the state saved in location 1 by pressing Recall 1 Enter
To select the power-on state of the ac source, proceed as follows:
1.
On the Function keypad, press Shift Output, and scroll through the Output
menu until you get to the PON state command.
Use the  and  keys to select either RST or RCL0. RST sets the power-on
2.
state of the unit as defined by the *RST command. RCL0 sets the power-on
state of the unit to the state saved in *RCL location 0.
To clear the non-volatile memory of the ac source, proceed as follows:
1.
On the Function keypad, press Shift Output and scroll to the *RST com-
mand. Then press Enter. This returns the unit to the factory-default settings.
2.
Save these settings to location 1. Press Shift Save 1 Enter.
3.
Repeat step #2 for memory locations 2 through 16..
58
Address
key. This menu is also used to select either the
Display
ADDRESS 5
ADDRESS 7
ADDRESS 5
INTF RS232
BAUDRATE 600
PARITY EVEN
Display
*SAV 1
*RCL 1
PON:STATE RST
*RST
*SAV 1
*SAV 2
*SAV 3
*SAV 4
.
.
...*SAV 16