Charging the Battery
WARNING
Charging the battery produces gasses that
can explode.
Never smoke near the battery and keep sparks
and flames away from battery.
Important:
Always keep the battery fully charged
(1.265 specific gravity). This is especially
important to prevent battery damage when the
temperature is below 0°C (32°F).
1.
Charge battery for 10 to 15 minutes at 25 to 30
A or for 30 minutes at 10 A.
2.
When the battery is fully charged, unplug
the charger from the electrical outlet, then
disconnect the charger leads from the battery
posts
(Figure
57).
3.
Install the battery in the machine and connect
the battery cables; refer to
(page
47).
Note:
Do not run the machine with the battery
disconnected; electrical damage may occur.
Figure 57
1. Positive battery post
2. Negative battery post
All manuals and user guides at all-guides.com
Installing the Battery
g000960
3. Red (+) charger lead
4. Black (-) charger lead

Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance, however, if a fuse blows check the
component and circuit for a malfunction or short.
1.
The fuses are located on right console next to
the seat
(Figure
2.
To replace the fuses, pull out the fuse to remove
it.
3.
Install a new fuse
1. Optional accessory—15 A
2. Charge—25 A
3. PTO—10 A
48
58).
(Figure
58).
Figure 58
4. Main—25 A
5. Console
g020464