MAGUIRE Weigh Scale Blender 4088 Installation Operation & Maintenance page 94

Touch screen controller
Table of Contents

Advertisement

ADDITIVES third:
The ADDITIVE dispenses occur last in the sequence. Each dispense must meet
requirements set by internal parameters.
MATERIAL RUNS OUT:
If any material runs out or is not enough to meet criteria set by parameters then the
process will NOT CONTINUE past this component. RETRIES of this dispense will
occur indefinitely until the full dispense occurs or the STOP button is pressed
followed by the ABORT button. The ALARM will sound after 4 retries (set by AL
parameter). See Component Parameters, AL parameter for the ALARM parameters.
If ALARM Occurs:
More than four retries of any single component will cause the Component Alarm and
activate the strobe light, audible alarm, and multiple on-screen alarm alerts. Every
alarm also logs to the Alarm Log. The component that is causing the alarm will
continue to retry the dispense. To continue with the dispense sequence, the
requirements of the dispense must be satisfied or the dispense aborted with the
Abort button.
WEIGH BIN dump:
After all dispenses the weigh bin is emptied by the final dump of the weigh bin into
the mixing chamber. The dump valve remains open for four seconds. (DTI
parameter)
SENSOR covered:
While the sensor is covered, the dump valve remains open to ensure the weigh bin
empties completely. Dispensing stops. The dump valve will remain open for as long
as the sensor is covered. This will be until the next cycle begins.
FLOW CONTROL Valve: (optional)
The Flow Control Valve under the mix chamber will stay closed for 6 seconds (FCV
parameter) immediately following a dispense into the mix chamber. The rest of the
time it opens when the sensor is covered, and closes when the sensor has been
uncovered for at least two full seconds (based on DLY parameter).