Component Setpoint Control – High / Low Limit
A component's maximum and/or minimum setting can be limited by an upper and/or lower
limit using the component parameters SE (upper) and SL (lower). When a limit is set, the
setpoint will be capped at the lower or upper limit. When an upper or lower limit is set for a
component, a Setpoint Limit Indicator will be visible on the components setpoint field and
will indicate if the setting is above, below or within the upper and/or lower setpoint limits.
The Setpoint Limit Indicator displays as a circle with an upper and lower half using the
colors white, green or red. The upper half is the upper limit (_SE parameter) and the lower
half is the lower limit (_SL parameter). White=no limit, green=within the limit set,
red=outside of the limit set. See page 66 for the SE and SL parameters.
Setpoint Limit Indicator Examples:
SE and SL within allowable limits.
SE within allowable limit, SL below allowable limit.
SE above allowable limit, SL within allowable limit.
SE disabled, SL within the allowable limit
SE disabled, SL below the allowable limit.
SE within allowable limit, SL disabled.
SE above allowable limit, SL disabled.