Instructions For Normal Operation - MAGUIRE Weigh Scale Blender 4088 Installation Operation & Maintenance

Touch screen controller
Table of Contents

Advertisement

Instructions for Normal Operation:

1. Fill HOPPERS.
2. Turn POWER ON. Verify correct Settings, Types and Mode of Operation.
3. Press START Button.
Blender will operate automatically, dispensing material until level sensor is covered.
Use the STOP Button to stop the blender. Turn POWER off only on final shutdown.
After several days of proper operation:
Save the current configuration including all parameters to the User Backup Settings for future
retrieval just in case software problems develop later. This routine is also useful prior to a minor
firmware update since a firmware update will reset most configuration information back to factory
defaults.
Note: During a firmware update, it may be better to reset all settings back to factory. This is
because an update to the latest firmware from a much older version of firmware may have
fundamental changes in the software.
To SAVE the configuration to the User Backup Settings:
Press
Display will prompt for a password. (default: 22222)
Press
System Configuration
Press
Resets
Press
User Settings
Press
Save User Settings
Press
Display will show the System Configuration categories.
Display will show the categories of System resets:
User Settings, Factory Access, Restore Factory Defaults,
Firmware Update.
Display will show Restore User Settings / Save User Settings.
Display will prompt for confirmation to save user settings.
To save the user settings including parameters
or press the red X to cancel and exit.
Then press: