MAGUIRE Weigh Scale Blender 4088 Installation Operation & Maintenance page 138

Touch screen controller
Table of Contents

Advertisement

Pump Configuration Fields
Blowback - Blowback is a pulse of air to clear the filter. Blowback has two
configuration fields. Skip cycle defines the number of Bypass cycles skipped
between each blowback pulse. Default for Skip Cycle is 10. Setting Skip Cycle to
0 (zero) will pulse every time. Time Interval is a multiplication factor of 400ms to
pressurize the charge canister. Default Time Interval is 5 (1=400ms).
IDLE TIME - The time in minutes that the pump runs after the last convey request
before shutting off.
BYPASS - The time delay in 10ths of seconds (0-50, zero seconds to 5 seconds)
before the Bypass valve opens after all receivers are satisfied.
PURGE RATIO - The % of time split between two purge valves. Used to clear
material that overshoots the receiver.
PUMP - Selects between pump A or pump B outputs.
Pump Labeling
Pressing the Pump's image in the center of the screen displays information about
the pump and allows the Pump's label and defaults can be reset.
138