TROUBLESHOOTING
The appliance has been tested before being put into service.
The information provided below is intended to assist in the identification and correction
of any anomalies and malfunctions which might occur during use.
The user can solve some of these problems himself, but for others specific technical
knowledge or skill is required, and so they must only be carried out by qualified staff
with recognised experience acquired in the specific sector of operation.
Important
For all requirements contact the agents or the headquarters of Angelo Po which
can be found in the contacts section of the website http://www.angelopo.com.

Fault

The appliance does not
switch on
Smell of gas
Cooking cycle does not start
or stops suddenly
The burner does not light or
goes out suddenly
Burner does not light or goes
IT
out suddenly with "E12"
alarm signalled
GB
DE
FR
ES
TABLE OF ALARM INDICATIONS
If the problem or fault noticed is not amongst those
listed in the table, consult the "Key to Alarms" table
provided below.
The information provided below s intended to identify
the alarm signals which appear on the display (7).
Important
Press button (12) to reset the alarm and the cook-
ing cycle restarts automatically; if this is not the
case, press the start key (16).
English
FAULT
Cause
Fuse "blown"
Safety or protection device (safety
thermostat or overload cutout)
tripped
Electronic circuit board damaged
Gas leaks in supply system
Control board electronic circuit board
damaged
Alarm triggered
Gas valve faulty
Air intake in base obstructed
Ignition plug wires disconnected or
damaged
Ignition plugs dirty or damaged
Ignition monitoring device faulty
Fault
- 24 -
Remedy
Replace the fuse (see page 38)
Press device reset button
Contact the after-sales service
Check the tightness of the system
Contact the after-sales service
Consult the "Key to Alarms" table
Replace gas valve
Clean the air intake
Reconnect or replace the wires
Clean or replace the plugs
Replace the device