Angelo Po FX Series Technical Manual

Angelo Po FX Series Technical Manual

Combi oven
Table of Contents

Advertisement

LEVEL 1 and 2
LEVEL 3
LEVEL 2
Rev.1
Copyright by Servizio Clienti ANGELO PO Spa
1

Advertisement

Table of Contents
loading

Summary of Contents for Angelo Po FX Series

  • Page 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 Rev.1 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 2: Table Of Contents

    Adjustment during the test......................64 4.5. Problems during the test setup wizard.....................67 4.6. Gas flue analysis..........................68 4.7. Installation report..........................69 4.8. Gas alarms and burner problem solving ...................71 4.9. Gas conversion ..........................74 4.10. Levels 2: Gas test ..........................75 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 3 Blower fan replacement ........................108 7.14. CPU and display LCD boards (LIV.3) replacing ................109 7.15. CPU and display LCD boards (LIV.3) replacing (2 version)............115 7.16. Roll-In adjustment RX201 - RX202....................117 7.17. Scheduled recommended maintenance ..................119 ALARMS ..............................120 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 4: Commercial Model Number

    1. COMMERCIAL MODEL NUMBER ( 2 – 3 ) Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 5 WITH RIGHT FX61G2R FX101G2R OPENING DOOR FX61G3R FX101G3R FX61E2CR FX101E2CR SPECIAL VERSION FX61E3CR FX101E3CR WITH FAT DRAIN AND RIGHT FX61G2CR FX101G2CR OPENING DOOR FX61G3CR FX101G3CR FX201E2P FX201E3P SPECIAL VERSION FOR PASTRY FX201G2P FX201G3P Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 6 FM GAS POWER (KW) DELTA % 16,7% 8,3% 25,0% 12,5% 20,35% 14,6% FX ELECTRICAL POWER 17,8 35,5 (KW) FM ELECTRICAL POWER 17,8 35,5 17,9 (KW) DELTA % 0,0% 0,0% 0,0% 11,7% 0,0% 0,0% Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 7: Connection Diagram Electric And Gas

    1.1. Connection diagram electric and gas OVEN CONNECTION DIAGRAM (FX122E3) Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 8 OVEN CONNECTION DIAGRAM (FX122G3) Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 9: Water Characteristics

    The appliance must be supplied with drinking water having the characteristics shown in the table. If these characteristics are not complied with, the appliance might suffer damage; a water treatment device should therefore be installed. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 10: Functional Diagram Combi Oven

    2. FUNCTIONAL DIAGRAM COMBI OVEN Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 11: Open Valve Operation

    - especially at high temperatures - in order to cool and condense the flow of moist air coming out. The condensate is collected on the bottom of the pipe to siphon 6 and conveyed through the rubber hose 14. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 12: Closed Valve Operation

    Note that, unlike than the FM, the condensate tube 14 is connected upstream of the swing of the siphon, as with the motorised valve closed the vent pipe 6 and the drain tube 14 are at the same pressure of the cooking chamber. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 13 Combi cooking mode: the user can set the desired % of steam - the opening and closing of the vent valve is controlled automatically by the oven, based on values detected from the apposite humidity probe. Steam cooking: valve remains closed. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 14: Drain Cooldown / Steam Condensing Operation

    It consists of: - Double water solenoid valve (one is for cleaning) - Pressure switch on the drain cooldown line - Pressure switch on the washing water line - Pressure reducer (only models FX201-202) Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 15: Steam Producing Operation

    Back flow preventer 2.4. Steam producing operation Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 16: Electronic Boards For Levels 2-3, Inverter, Fuses, Overload Relays

    LCD board 1b keyboard (glued to the glass panel) 1c LED board 1d 2. power PCB 3. combustion and fan control PCBs (only gas model) 4. inverter 5. USB connector 6. transformer 7. on/off switch Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 17 4. Inverter 1. Control panel The control panel has to be connected always on the 1 connector 2. Power board and Switch 3. Combustion Control board and Blower Control board Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 18 5. USB plug 1b. LCD display 1a. CPU board 1d. LED board 1c. Keyboard Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 19 2 FW Transformer 2x 12Vac outputs (fused) to the electronic boards Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 20 Software (SW) - Contains all the user interface, programs, pictures, etc.. – it is in the CPU Operating System (OS) – it is in the CPU Versions of OS, SW and FW are shown in the upper part of the Service menu. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 21: Service" Menu

    O.S.: 1.9 The operating system, indicates the date issued and version used in that machine. The issue date of O.S. is unique and allows the user to know the last upgrades of the oven. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 22 At the end of the configuration the oven shows the list of devices found: check that the devices are the same as those installed. If the devices do not match check again the oven and repeat the process of configuration. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 23 Operate as follow: Enter the service menu Select the "oven type" Select the type of oven Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 24 Temperature: Allows you to configure the temperature unit used in the normal operation of the oven. The choices can be °C or °F. To change the setting, put the cursor on the line "Temperature" and select the new unit pushing the knob. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 25 How to update the parameters (SW and FW alignment) This procedure allows the user to align the parameters of the boards after replacing the CPU board or power board. The procedure is performed after replacing the card, as follows: Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 26 Pump unit selection: set 0 if is installed the black/brown pumps unit, set 1 if is installed the blue pumps (first version). T/RH display: This option is for internal use of Angelo Po. Counters: displays the numbers of washing programs performed and the working times at low and high temperature.
  • Page 27 Core probe warning: This option is for internal use of Angelo Po. OS update: This option is subject to password and is for internal use of Angelo Po. Restore Factory PSW: Replaces the user entered password with the password APGC. To be used if the user forgets their password.
  • Page 28: Explanation Table

    Note: After replacing one of the items listed above, at the first ignition of the oven you may see alarms E13 and / or E20. After following the procedures listed in the table the alarms should no longer appear. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 29: Inverter

    Cooling fan Once you remove the power supply on the oven, you have to wait 3 minutes before starting maintenance on the inverter or the motor due to electrical hazards. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 30 GND check the correct connection of the motor and E06:40 check that the phase W of motor supply is not Phase W short circuited to GND short circuited to the GND Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 31 E06:100 Inverter checksum error Replace the inverter E06:122 Inverter control section faulty Replace the inverter check the connection between terminal 1 and E06:255 Inverter blocked terminal 11 on the inverter. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 32: Electronic Boards Level 2 General Layout

    1. control panel assembly, it is made of: o CPU board 1a o keyboard (glued to the glass panel) 1b 2. power PCB 3. combustion and fan control PCBs (only gas model) 4. inverter 5. transformer 6. on/off switch Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 33 2. Power board 2. Power board 1. Control panel The control panel has to be connected always on the 1 connector 3. Combustion control board and blower control board Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 34 1b. Keyboard 1a. CPU board Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 35 (3) (for gas model only) via RJ45 network cables. If there is no communication between the power board and the CPU board or the combustion control board the alarm E13 appears (communication failed error). Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 36 (° C or ° F). b) Press the “time” button and turn the knob to set the automatic preheating c) Hold the "washing" button for at least 3 sec to see the SW and FW versions. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 37 " USb " is steady and also turns on the START / STOP button in green color. The stick (recommended max. size 4GB) must be formatted FAT or FAT32 and contain a directory "AngeloPo_L1_L2" with all the necessary files inside). . Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 38 If the configuration is incorrect check the connections between the boards and press the knob to repeat the configuration. o If the configuration is correct press the "start / stop" button to exit. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 39 61E2, 82E2, 101E2, 122E2 1 - 0 201E2, 202E2 2 - 0 61G2, 82G2, 101G2, 122G2 1 - 1 201G2, 202G2 2 - 2 Oven type Number of Number of Combustion Control Inverters boards Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 40: Explanation Table

    Note: After replacing one of the items listed above, at the first ignition of the oven you may see alarms E13 and / or E20. After following the procedures listed in the table the alarms should no longer appear. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 41: Fx Fuses Description

    Blower control pcb: F1- board general fuse (4A F), blower and combustion control board supply circuits. Combustion control pcb: F1----- board general fuse (6,3A T), protects also gas valve supply circuit. NOTE: T=slow, F=fast. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 42: Operation Testing, Adjusting, Installation Report, Gas Circuit Alarm

    To make this adjustment it is necessary to use a gas flue analyzer. Furthermore, an electronic variable-speed blower, controlled by the power board, allows you to change the quantity of the air-gas mixture. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 43: Power Schemes

    Full power*: operating at maximum capacity and blower engines at full speed, the • inlet gas circuit is in total decompression and the gas valve adjustment of the valve does not cause significant differences. The combustion is totally dependent on the nozzle installed. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 44 * With the PLUS function turned off the oven works with maximum set at 90% of maximum power, to use 100% of the power it is necessary to enable the PLUS function. NOTE: - The burner ignition occurs at a power of about 10% higher than the minimum (40-50%). Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 45: System Components

    - As the gas inside the tube (7) and the fitting (3) is at negative pressure, in case of leak to find it don’t use flame because it could be sucked in the mixer and cause a fire / explosion. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 46 Functional diagram gas system Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 47: Gas Valve ( Csa Approved)

    4.2.1. Gas valve ( CSA approved) 120 VAC between terminals 3 and 4 Compensation pipe Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 48: Mixer

    Check that the draft air tube is free of cuts or tears and that the clamps are tight Check the connections tightness; do not use flames on gas burner because they could be sucked into the mixing circuit and cause fire / explosion. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 49: Air Blower Fan

    Air blower fan Power supply 115 volts AC Modulation control NOTES: Do not force the connector of the modulation control, it is one way inserting. The blower speed is controlled by the blower control board. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 50: Blower Control Board

    On the level 3 models the microAmpere reading can be displayed. It is possible to activate this function from the Service menu; the reading needs to be divided by 10 (e.g. 32 / 10 = 3,2 microAmpere). Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 51: Combustion Control Board

    The reading must be about 3,5 µA DC; in order to check it, take the mesure in series between the flame detector and the terminal n°8 on the combustion control board, as shown in the drawing. 4.2.5. Combustion control board Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 52: General Functional Diagram

    REQUEST PHASE RECEIVED NEUTRAL 120 V 100 – 240 V 120 V INVERTER POWER SUPPLY 120 V LOCKOUT ALARM 120 V BURNER-ON RS485 FEEDBACK COMMUNICATION CLOSE ON POWER REQUEST 120 V LOCKOUT RESET Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 53: Spark Plug And Flame Detector Kit

    - The spark plug needs scheduled maintenance, see section 4.10. - We recommend the replacement of the gasket each spark plug replacement. - The spark plug kit is one way fixing (see picture). Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 54: Burner

    4.2.8. Burner INSULATING MATERIAL COIBENTANTE NOTES: Replace the insulation panel at any replacement of the spark plug kit, if necessary. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 55: Heat Exchanger

    4.2.9. Heat exchanger FX heat exchangers are more efficient because they have more exchange surface than FM ones: +18% 101: +13% +22% 122: +10% 201: +13% 202: +10% Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 56: Exhaust Extraction Kit

    If the oven is not positioned under a fume hood, you can use the Exhaust extraction kit to make a connection to an exhaust system. It is absolutely prohibited the direct connection to the outside. A type installation only! Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 57: Blower Control Board: Logic Operation

    This step will remain until the power is requestd and/or until an alarm occurs, then step 10 is selected. STOP: burner turned off. The blower is set to stop. The blower control check for alarm from Burner Control Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 58 If there is any alarm then step 7 and 8 are selected. If there are problems the board turn on state “7” or "8" ( Locked Steps ), showing alarm. For example GAS: F4 can be reset from the panel. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 59: Ignition Standard Cycle

    The diagram shows 2 ignition cycles (step 1-5): the first operational phase (step 5) has a modulating working, second, minimum power range working. The difference between the two cycles is the speed of the blower, which varies with the required power. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 60: Gas Alarm: F4: Flame Missing

    After these 3 attempts the combustion control board goes into state "8” the combustion is blocked and the display shows the alarm GAS: F4. The alarm can be reset by the user. The causes may be different, for details please refer to section 4.8 Gas Alarms. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 61: Gas Setup

    (see section 6. Change of Gas). 4. To start the wizard, select "Burner 1. (For models FX201G3 and FX202G3 perform first the procedure on the burner 1 and thereafter on the burner 2). Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 62 Verify that the ignition occurs at the correct speed and that the minimum and maximum speeds reached match those settings. If the gas system doesn’t function properly or the flue combustion values are not included in the ranges indicated, follow the instructions in section 4.4.3 Adjustments. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 63: Recommended Values Of Combustion

    ± 0,8 0÷100 FX202G. CO2% Range CO2% CO ppm minimum 9,3% ± 0,8 0÷100 Natural Gas G20 Maximum 9,2% ± 0,8 0÷100 minimum 11,5% ± 0,8 0÷100 Propane G31 Maximum 11,1% ± 0,8 0÷100 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 64: Adjustment During The Test

    Once done repeat the wizard test. When the adjustment is finished refit the protective cap of the screw. Attention: the pressure adjustment screw PR.ADJ. has no effect on increasing the power of the oven. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 65 Select the parameter you want to change and set a different value depending on the problem (see next paragraph). Attention: never increase the maximum blower speed over the value set by the factory. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 66 30% - 65% - Propane VMax 6500 7000 6500 6500 7000 6700 5500rpm - Methane 7000rpm VMax 6000 6000 6000 6000 6500 6000 Propane VAcc 35 - 60% Methane - Propane Ramp 30000 10000-30000 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 67: Problems During The Test Setup Wizard

    Important: At the end of each intervention on the gas system must perform the procedure for testing gas by measuring the CO and CO2, and verify that the data is within the fields declared by the manufacturer. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 68: Gas Flue Analysis

    CO2 and CO values. Wait until the measure has stabilized (about 1 minute). The gas analyzer should be calibrated and checked periodically to make precise measures. Recommended analyzer: Testo 327-2. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 69: Installation Report

    When first installed, the installer must fill in all parts of the following installation report and send it to "Angelo Po" within 7 days for the activation of the Warranty. It presents data connection, and in particular must show the power supply, if possible, the mains water pressure (and other available data, e.g.
  • Page 70 CO max: 300 ppm Instrument Used (mark and model):………………………………………………………………… This form, relative to the appliance indicated above, filled-in completely must be sent to Angelo Po SpA within 7 days from installation in order to activate the warranty. Certification: the under-signed, in quality of technician of an Angelo Po authorised after-sales centre, certifies that all of the items on this form have been filled-in correctly and that the unit is installed correctly.
  • Page 71: Gas Alarms And Burner Problem Solving

    3 fast light + 1 long light = Failure before ignition step or leakage currents from flame signal wire or from his plug. From 8 to 14 fast light + 1 long light: internal failure. Change the burner control board. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 72 The flame is lighting but after some 3. check the small led on the burner control board for status seconds the flame goes off. informations and/or diagnostic mode. 4. measure the ionization current. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 73 (Pins 4-4 and Pins19-3 between two pcb ). Note: For the 20 grid models appears with the alarm also the number of the burner; 1 stands for the lower burner and 2 stands for the upper burner. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 74: Gas Conversion

    2. Setting the type of gas on the display: o enter menu “Service” (Password:SAAP), o enter menu “Setup gas”(Password:SI74), o select the type of gas used from the menu “Type of gas” 3. Perform analysis of flue gas (see section 4.6) Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 75: Levels 2: Gas Test

    2. Type of gas: the first display shows the kind of gas: turning the knob is possible to choose the type of gas G20, G25, G30, G31 and Out; the selection is confirmed with enter with the knob. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 76 5. Start testing: the START/STOP button is on, press it to start the testing phases. 6. STEP 1: Ignition and burner at minimum power. Go to step 2 with button ECO. 7. STEP 2: Burner at maximum power. Go to step 3 with button ECO. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 77 10. Change the dei parameters of the gas board: This adjustment must be done only in according with Service Angelo Po. The parameters into “Step 2” and “Step 3”, are modifiable: press the button TEMPERATURE (red) to change the maximum speed, TIME (yellow) to change the minimum speed, HUMIDITY (green) to change the ignition speed.
  • Page 78: Periodic Gas Flue Analysis

    2500 working hours. Also in this case you can erase it temporarily by pressing button RESET, and you can work normally with the oven until next switching on. To remove the warning for longer time you must perform Setup Gas and make gas flue analysis. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 79: Washing Cycles Levels 3

    Through this pipe the chemical reaches the nebulizer cleaning in the heat exchanger compartment. PUMP 8 INJECTORS SPRINKLER DETERGENT TANK MIXING PUMP TANK SANITIZER TANK WATER SUPPLY FIXING SPRINKLER WATER SOLENOID PRESSURE NON-RETURN ADJUSTMENT VALVE EN17171 COOKING CHAMBER TO DRAIN SIPHON DRAIN SOLENOID Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 80 Soft clean: 1 detergent dispensing + 1 sanitizer distribution (small amounts) Basic clean: 1 detergent dispensing + 1 sanitizer distribution Medium clean: 2 detergent dispensing + 1 sanitizer distribution Standard clean: 3 detergent dispensing + 2 sanitizer distribution Descaling: 1 sanitizer distribution Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 81 - Since version 2.xx each time you switch on the oven, it runs for 5 seconds the dosing pumps, then it opens for 0.5 seconds the rinsing solenoid valve and then it empties the tank for 20 seconds. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 82: Clean Test

    During all stages the status of the float shows on the display: it must be open when the tank is empty, it must be closed when the liquid level in the tank exceeds half. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 83: Washing Interruption

    (Ø 9-10 mm). WARNING: on oven level 2 the diaphragm does not have to be drilled. Diaphragm Diaframma Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 84 LEVEL SENSOR TO THE SPRINKLERS MIXING TANK WATER INLET DRAINAGE PRESS. SWITCH SOLENOID VALVE DETERGENT DISPENSER MANOMETER SANITIZER DISPENSER WATER SOLENOID VALVE PRESSURE REDUCER TO SIPHON NON RETURN VALVE WATER DRAIN Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 85: Washing Alarms Table

    CLEAN TEST phase. Circuit loading incomplete Carry out the CLEAN TEST The washing cycle has been interrupted during the rinsing stage, Carry out the CLEAN TEST caused by “missing water” Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 86 Check the pressure of water supply, control the power During phase 3 the water doesn’t fill supply rinse solenoid (terminal 17 on the power board), the tank. check fuse F5, check the pressure regulator. Replace the solenoid. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 87 (if not just replace the whole solenoid valve). During Phase 4 the liquid level into the tank flow down but the float Replace the float level sensor. level sensor doesn’t switch. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 88: Cleaning Consumption Table

    5.5. Cleaning consumption table Drain cleaning function: Selectable only for the cleaning programs Standard and Medium. For all oven sizes the consumption of detergent increases 0.13 kg. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 89: Cleaning Warning And Cleaning Blockage

    Here following the two screens: The timing of these two types of alarms can be set by the user by going to "settings", "user parameters", typing the password "APGC" and entering the following screen: Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 90 Release cooking: unlock the oven without having to run a cleaning cycle if it is expired "time limit cleaning oven". In the alarm log the warning is registered with “W01” and the blockage with “CLE”. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 91: Warning Descaling

    5.7. Warning descaling The warning screen appears after a time set by user, by which you should run a descaling. In the alarm log the warning is registered with “W02”. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 92: Washing Cycles Levels 2

    • Water solenoid valve (water inlet assembly) • Pressure switch (water inlet assembly) • A hose connection ( to connect the rubber hose with the Teflon tube) • Fixed sprinkler in the cooking chamber Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 93 In case of low pressure or broken solenoid valve the alarm E26 will appear. The level 2 ovens have 2 cleaning programs: “CLE” “Pr” “P01” and “CLE” “Pr” “P02” selectable with the cleaning button. The cleaning program P02 performs twice the cleaning program P01. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 94: Dismantle And Reassembly Components

    3. the pin on the encoder goes into the hole on the spacer (picture 3) ; 4. All the assembly should be put in place with the pin into the hole on the dashboard (picture 4). PICTURE 1 PICTURE 2 PICTURE 4 PICTURE 3 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 95: Motor

    (see photo 4). When replacing the Corteco it needs flattening with MOLIKOTE 41. For removal, you should use the extractor p/n 6003060. PICTURE 1 PICTURE 2 PICTURE 3 PICTURE 4 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 96: Door Micro-Switch

    1. micro-switch position in the dashboard inner side (picture 1); 2. micro-switch holder fixing screws (picture 2); PICTURE 1 PICTURE 2 NOTE: the magnet for the micro switch is inside the door assembly. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 97: Door Glass Frame Disassembly

    Pull off the inner glass with its frames glued. To do this you must open the inner glass at about 90 ° to the door. Then lift up the hinge pins from the parade support. 90° Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 98: Component Compartment Cooling System

    6. air intake filter and air intake filter for gas valve (picture 6). PICTURE 1 PICTURE 2 PICTURE 3 PICTURE 4 PICTURE 6 PICTURE 5 NOTE: If the cooling motor breaks the following alarm will appear: “components compartment over temperature E10” (see chapter Alarms). Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 99: Door Adjustment

    (see photo 4).When the adjustment is done, work with the oven on steam to check the tightness of the door gasket. PICTURE 1 PICTURE 2 PICTURE 3 PICTURE 4 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 100: Core Probe

    2. the correct positioning of the probe is shown in the picture 2; 3. the terminals of the probe are connected to the power board, the white one on the plug 73, for the others is the same. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 101: Humidity Probe

    1. the humidity probe is inside the chamber, behind metal panel (picture 1). 2. the terminals of the probe are connected to the power board (picture 3). PICTURE 2 PICTURE 1 PICTURE 4 PICTURE 3 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 102: Halogen Lamp Replacement

    2. to replace the lamp, unscrew the glass fixing nuts into the chamber (picture 2); 3. under the right hand panel it is possible to work on the lamp holder and the plug (picture 3). PICTURE 2 PICTURE 1 PICTURE 3 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 103: Lock Dismantling

    7. mount the lock – handle assembly on the door with the three screws. Add on each screw Loctite 243 (pictures 7a and 7b). Before securing the screws control the vertical alignment of the handle. PICTURE 1 PICTURE 2 PICTURE 3 PICTURE 4 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 104 PICTURE 5a PICTURE 5b PICTURE 6 PICTURE 7a PICTURE 7b Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 105: Lock Dismantling 20 Trays Models

    6. Unscrew the screw rear handle lock for its removal (picture 6); 7. to access the lock assembly (picture 7) remove the panel behind the lock (picture PICTURE 2 PICTURE 1 PICTURE 3 PICTURE 4 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 106 PICTURE 5 PICTURE 6 PICTURE 7 PICTURE 8 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 107: Spark Plug Replacement

    3. Unscrew the nuts on the spark plug fixing pins. (picture 3) 4. Take off the spark plug and remove the gasket. (picture 4) PIC. 1 PIC. 2 PIC. 4 PIC. 3 NOTE: with the spark plug always replace the gasket too. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 108: Blower Fan Replacement

    (internal and external) FX61G3 FX101G3 FX82G3 Ø16 - 3138640 Ø20 - 3138660 Ø24 - 3138650 Diaphragm FX122G3 FX201G3 FX202G3 Ø30 - 3138670 Ø19 - 3171770 Ø25 - 3172410 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 109: Cpu And Display Lcd Boards (Liv.3) Replacing

    7.14. CPU and display LCD boards (LIV.3) replacing To access the replacement of such components, unscrew the two screws TE M5 placed on the bottom of the dashboard that opens like a book. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 110 7 – Net cable (connection with the power board) 8 – Keyboard flat cable 9 – LED board flat cable 10 – External buzzer connection (optional) WARNING: DO NOT CONNECT THE POWER SUPPLY TO THE PLUG 10. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 111 10 – Connection with blast chiller (optional) WARNING: DO NOT CONNECT THE POWER SUPPLY TO THE PLUG 10. 11 – Network cable (optional) A – CPU B – Keyboard C - Encoder Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 112 To reconnect the flat it must be threaded into the connector until it comes to the bottom. Then lock the cable pushing the clip down as shown in the photo below. POSIZIONE “SBLOCCATO” POSIZIONE “BLOCCATO” UNBLOCKED POSITION BLOCKED POSITION Fermaglio clip clip Fermaglio Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 113 LCD display replacing To remove the LCD screen, first remove the CPU board. To remove the display you must remove the metal profile shown in the picture. DISPLAY FIXING PROFILO FISSAGGIO PROFILE DISPLAY Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 114 To remove the flat connection from the display plug, unlock the clip by rotating it as shown in the picture. Remember to lock again the flat cable. POSIZIONE SBLOCCATO POSIZIONE BLOCCATO BLOCKED POSITION UNBLOCKED POSITION Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 115: Cpu And Display Lcd Boards (Liv.3) Replacing

    Since March 2014 we have introduced new CPU boards and Keyboards. The new cards are compatible with the previous version. The new CPU has connectors for flat cables (keyboard) type of old and new. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 116 KIT CPU for updating ovens 1 version The new CPU can be used to update older versions using an adaptation kit: CPU board mounted with KIT Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 117: Roll-In Adjustment Rx201 - Rx202

    7.16. Roll-In adjustment RX201 - RX202 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 118 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 119: Scheduled Recommended Maintenance

    Run pump test procedure – check the pumps working Check possible leaks on the fittings of the pumps Check and possible adjustment rinse water pressure Disassemble multi-injector sprinkler and check possible obstructions Clean inverter air intakes Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 120: Alarms

    See chapter 4.8 (alarm gas chart) too low, or flame the problem persists repeated inform the after-sales more than detection failure. service. once. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 121 3, the multipoint core wires are probe cannot service if it is faulty. connected to terminals 74-75-76-77-78 (Short circuit) be carried out. (wires red-yellow-blue-green-black) of the expansion PCB, and the white one is connected to terminal 73. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 122 (L3). For L3 only, tripped. service. cooking check the inverter alarm list. Check the cycles can be motor to rotate free and the 3 phases carried out. in case of 3 phases power supply. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 123 E13 = Power Board - CPU diagnostics service. cooking E13a= Inverter 1 tripped. cycles can be E13b= Combustion control board 1 carried out. E13c= Inverter 2 E13d= Combustion control board 2 Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 124 The oven’s functions are enabled so cooking Valve not Check the connector terminals on the Press reset button cycles can be working valve and on the power board. carried out. Washing programs are disabled. Copyright by Servizio Clienti ANGELO PO Spa...
  • Page 125 Check all the wirings relative to service. the ignition system. Check the correct insulation of the cable. Inform the E80 – E85 after-sales service. Copyright by Servizio Clienti ANGELO PO Spa...