Fault; Troubleshooting; Table Of Alarm Indications - Angelo Po AT 61G Use Manual

Acto oven
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 44

TROUBLESHOOTING

The appliance has been tested before being put into service.
The information provided below is intended to assist in the identifi cation and correction of any
anomalies and malfunctions which might occur during use.
The user can solve some of these problems himself, but for others specifi c technical knowledge
or skill is required, and so they must only be carried out by qualifi ed staff with recognised
experience acquired in the specifi c sector of operation.
Important
For all requirements contact the agents or the headquarters of Angelo Po which can be
found in the contacts section of the website http://www.angelopo.com.

Fault

The appliance does not
switch on
Smell of gas
Cooking cycle does not start
or stops suddenly
The cleaning cycle does not
start or stops suddenly
The burner does not light or
goes out suddenly
Burner does not light or goes
out suddenly with "E12" alarm
signalled
GB

TABLE OF ALARM INDICATIONS

If the problem or fault noticed is not amongst those
listed in the table, consult the "Key to Alarms" table
provided below.
The information provided below s intended to identify
the alarm signals which appear on the display (A).
Important
Press RESET to reset the alarm and the cooking cy-
cle restarts automatically. Press START if the cook-
ing cycle does not restart automatically.
3354462_ATG_ut_GB
FAULT
Cause
Fuse "blown"
Safety or protection device (safety
thermostat or overload cutout) tripped
Electronic circuit board damaged
Gas leaks in supply system
Control board electronic circuit board
damaged
Alarm triggered
Control board electronic circuit board
damaged
Alarm triggered
Gas valve faulty
Air intake in base obstructed
Ignition plug wires disconnected or
damaged
Ignition plugs dirty or damaged
Ignition monitoring device faulty
- 36 -
Remedy
Replace the fuse (see "installation
manual")
Press device reset button
Contact the after-sales service
Check the tightness of the system
Contact the after-sales service
Consult the "Key to Alarms" table
Contact the after-sales service.
Consult the "Key to Alarms" table
Replace gas valve
Clean the air intake
Reconnect or replace the wires
Clean or replace the plugs
Replace the device
A
ENGLISH

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents