D6011/D6051 Series Double Unit Pull Side Power Operator

General Information

Operation:
Your Low Energy Operator can be configured in three variations to meet the standards:
1. Push plates, Wave-to-open switches, etc. are available to activate the operator.
2. Push & Go can be enabled. In this mode, your door is pushed (or pulled) slowly 15° manually, and then
automatically opens to full open position.
3. Door can be used as a manual door. The door will work and act like a standard door closer, with or without power,
when pushed or pulled open manually. If Push & Go is enabled and door is opened quickly, door will function as a
manual door (energy save feature). Push plates are still active.
If desired, overhead presence devices can be provided for an extra level of protection. Consult local authority having
jurisdiction. These are not required by current ANSI/BHMA A156.19 standards.
Opening:
When an opening signal is received by the control unit, the door opens to the fully open position. The open position is
held by the motor and is adjustable from 0 to 30 seconds. If the door is obstructed while opening, the door will stop; the
operator will sense obstruction (obstruction time is adjustable from 0 to 5 seconds) and the door will close.
NOTE: Door must be visible by person operating activation switch(s). Switch(s) to comply with ANSI/BHMA
requirements. Auxiliary door stop (by others) required.
Closing:
When the hold open time has elapsed, the door closer will close the door automatically. The door will slow to low speed
at latch before it reaches the fully closed position. The door is kept closed by spring force of the closer. If the door is
obstructed while closing, the door will stop against the obstruction; the operator will sense obstruction and reopen to
fully open position after obstruction time has been reached. Once the hold open time has elapsed a second time, the
door closer will close the door automatically. If the door is obstructed during this second closing cycle, the door will
stop and rest against the obstruction using only the force of the closer spring. To reset, allow door to fully close and re-
activate push plates to test operation.
Infinite Hold Open:
An optional feature to be used if door is desired to be held open for more than 30 seconds.
Set selector mode switch on underside of union assembly to hold open. Door will immediately begin to open to the fully
open position. Once door is fully open, brake on end of motor energizes holding door in open position. To release from
hold open, if door is set up for executive operation (see Double Door Hard Wired Executive Function Wiring on page
20 or Double Door Radio Frequency Executive Function Wiring on page 22), door can be closed with activation
device. A pull on the door will also allow the unit to be taken out of hold open. Once door has closed, the door will
reopen to fully open position unless activation device is pressed or selector mode switch is changed from hold open
position.
NOTE: Door must be visible by person operating activation switch(s). Switch(s) to comply with ANSI/BHMA
requirements. Auxiliary door stop (by others) required.
Copyright © 2019, 2020, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1029-020 Rev 6 01/23
WARNING: Make sure (120V, 60Hz) input power
is turned OFF at facility's main circuit breaker
before proceeding with installation
Approved 2023-01-24
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norton rixson d6011 series

Table of Contents