Finalize Installation; General Electrical Information - Assa Abloy NORTON RIXSON D6051 Series Installation Instructions Manual

Double unit pull side power operator
Hide thumbs Also See for NORTON RIXSON D6051 Series:
Table of Contents

Advertisement

D6011/D6051 Series Double Unit Pull Side Power Operator

Finalize Installation

Adjust covers to finalize installation
1. Align cut-outs in each cover to
corresponding pinion shafts. (Figure 31)
2. Slide covers onto units using end caps and
union spacers as guides.
NOTE: Verify all wiring and sheet metal
guards are inside cover.
3. Snap covers securely to backplates. Pull on
covers to verify they are secure.
NOTE: If cover will not securely snap onto
backplate, verify backplate is not warped or
twisted. Additional support or shimming may
be required. See Sections A & B under Prepare
Frame and Door.

General Electrical Information

y Power inputs at power input connection and
power output contacts must be made with
copper wire only.
y Maximum wire size:
12 AWG at power input connection
14 AWG at all other terminals.
y Power input at terminals LINE and NEUTRAL
must be 120VAC at 60 Hz (+10%, -15%)
Auxiliary Dry Contacts
Powered Output
Contacts
Copyright © 2019, 2020, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1029-020 Rev 6 01/23
WARNING: Make sure no wiring is loose or can be
caught by cover when it is snapped into place.
Approved 2023-01-24
Pinion Shaft Cut-out
Figure 31
y Maximum current draw from auxiliary
devices is 1.3 amps.
y All wiring and connections use standard
wiring practice conforming with local wiring
codes.
y Labeled fire or smoke barrier door
assemblies require 120VAC 60Hz power
input be supplied through normally closed
alarm contacts of the alarm system / alarm
panel.
Power On/Off
Switch
Power Input
and Basic Aux
Connection
Pinion Shaft Cut-out
Powered Output
Contacts
Auxiliary Dry Contacts
15