Automation Interface; Rint X12 Robot Interface; Busint X11 Industrial Bus Interface - EWM Taurus XQ 355 Basic Operating Instructions Manual

Table of Contents

Advertisement

5.6.1

Automation interface

No function of the external interrupt equipment (emergency stop switch)!
If the emergency stop circuit has been set up using an external interrupt equipment
connected to the interface for automated welding, the machine must be configured for
this setup. If this is not observed, the power source will ignore the external interrupt
equipment and will not shut down!
Remove jumper 1 on the corresponding control board (to be done only by qualified service
personnel)!
These accessory components can be retrofitted as an option > see 9 chapter.
Pin
Input /
Output
A
Output
D
Output
(open collec-
tor)
E/R
Input
F
Output
G/P
Output
H
Output
L
Input
M
Output
N
Output
S
Output
T
Output
Accuracy type ± (0.05 V+2.5 % of the measured value)
[1]
The operating mode is specified by the wire feeder (the start / stop function corresponds to the opera-
[2]
tion of the torch trigger and is used, for instance, in mechanized applications).
Accuracy type ± (0.02 V+2.5 % of the measured value)
[3]
5.6.2

RINT X12 robot interface

The standard digital interface for mechanised applications

Functions and signals:
Digital inputs: start/stop, operating modes, JOB and program selection, inching, gas test
Analogue inputs: control voltages, e.g. for welding performance, welding current, etc.
Relay outputs: process signal, ready for welding, system composite fault, etc.
5.6.3

BUSINT X11 industrial bus interface

The solution for easy integration with automated production with e.g.
Profinet/Profibus
EnthernetIP/DeviceNet
EtherCAT
etc.
099-005667-EW501
22.09.2021
Name
PE ------- Connection for cable screen
IGRO ---- Current flows signal I>0 (maximum load 20 mA /
15 V) 0 V = welding current flows
Not-Aus - Emergency stop for higher level shut-down of the
power source.
0V -------- Reference potential
IGRO ---- Current relay contact to the user, potential-free
(max. +/-15 V / 100 mA)
Uist ------ Welding voltage measured against pin F, 0-10 V
(0 V = 0 V; 10 V = 100 V)
STA/STP Start = 15 V / Stop = 0 V
+15 V ---- Power supply (max. 75 mA)
-15 V ---- Power supply (max. 25 mA)
0 V ------- Reference potential
Iist -------- Welding current measured against pin F;
0-10 V (0 V = 0 A, 10 V = 1000 A)
Design and function
WARNING
[1]
[2]
[3]
Interfaces for automation
Figure