Technical data
Taurus XQ 355 Basic
8.2
Taurus XQ 355 Basic
Welding current (I
Welding voltage according to standard (U
Duty cycle DC at 40° C
Mains voltage
Frequency
Open circuit voltage (U
max. Connected load (S
Generator rating (Rec.)
Power consumption P
Maximum mains impedance (@PCC)
Cos φ / efficiency
Protection class / Overvoltage category
Contamination level
Insulation class / protection classification
Residual current circuit breaker
Noise level
[6]
Ambient temperature
Machine cooling / Torch cooling
Mains connection cable
Workpiece lead (min.) / EMC class
Safety marking
Standards used
Load cycle: 10 min. (60 % DC ≙ 6 min. welding, 4 min. pause)
[1]
Multi-voltage device - Adjusting the power source to the mains voltage
[2]
Safety fuses are recommended DIAZED xxA gG. When using automatic cutouts, the "C" trigger chara-
[3]
cteristic must be used.
Power in idle mode without wire feeder.
[4]
This welding equipment does not comply with IEC 61000-3-12. When connecting a welding machine
[5]
to a public low-voltage supply system, the manufacturer or operator has to consult the electricity utili-
ties to make sure the welding machine may be connected.
Noise level during idle mode and operation under standard load according to IEC 60974‑1 at the maxi-
[6]
mum operating point.
Ambient temperature dependent on coolant! Observe coolant temperature range!
[7]
44
)
2
[1]
/ Tolerance / mains fuse
[2]
)
0
)
1
[4]
0
[5]
[7]
MIG/MAG
)
14,3 V to 31,5 V
2
3 x 380 to 400 V / -25 % to +20 % / 3 x 25 A
[3]
3 x 440 to 480 V / -25 % to +15 % / 3 x 20 A
82 V to 98 V
13,9 kVA
Type B (recommended)
Fan (AF) / gas or water
See declaration of conformity (appliance documents)
MMA
5 A to 350 A
20,2 V to 34,0 V
10,2 V to 24,0 V
350 A (100%)
50/60 Hz
82 V to 102 V
15 kVA
10,6 kVA
20,3 kVA
21 W
96 mOhm
0,99 / 90 %
Ⅰ / Ⅲ
3
H / IP 23
<70 dB(A)
-25 °C to +40 °C
H07RN-F4G4
70 mm
/ A
2
/
/
099-005667-EW501
TIG
22.09.2021
Need help?
Do you have a question about the Taurus XQ 355 Basic and is the answer not in the manual?