Gap Check
Enable
Disable
END------------------------------------
SR60 Scanner Programmer's Reference Manual
Chapter 4 — Enabling and Configuring Symbologies
---------
---------

Label Length Format

The following two sections explain how to set the Codabar Label
Length Format to either the Variable Length or Fixed Length
Format.

Variable Length Format

You can set the Codabar symbology to Variable Length Format.
To set the Codabar symbology to Variable Length Format
1 Identify the minimum length setting you want to make. The
selectable range is 03 to 50 characters.
Note: For this symbology, the scanner decodes up to 50
characters, but the actual length read varies depending upon
the interface type, bar code physical size, and print quality.
2 Scan the SET bar code.
3 Scan the Enable Variable Length Format bar code.
4 Scan the Set Minimum Label bar code.
5 Using the Digits bar codes on page 102, scan the digits to set
the minimum label length you identified in Step 1.