Chapter 4 — Enabling and Configuring Symbologies

Configuring the Code 128/and UCC/EAN 128 Options

Minimum Label Length

SET------------------------------------
Set Minimum
Label Length
84
Scan the following bar codes to configure the Code 128 and
UCC/EAN 128 options.
Minimum Label Length
You can set the Code 128 and UCC/EAN 128 Minimum Label
Length.
To set the Code 128 and UCC/EAN 128 Minimum Label Length
1 Identify the minimum length setting you want to make. The
selectable range is 00 to 80 characters.
Note: The scanner decodes up to 80 characters, but the actual
length read varies depending upon interface type, the physical
size of the bar codes, print quality, and whether the bar code
data consists of Code 128 code set A, set B, or set C
characters. (Because the C128 character set C allows for more
densely packed data, if the bar code includes all or mostly
C128 set C characters, more characters can be decoded).
2 Scan the SET bar code.
3 Scan the Set Minimum Label Length bar code.
4 Using the Digits bar codes on
the minimum label length you identified in Step 1.
Note: To set a label length less than ten, you must scan a zero
digit first and then the length digit (such as 04, 06, or 08).
5 Scan the END bar code.
---------
SR60 Scanner Programmer's Reference Manual