ZyXEL Communications MES3500-24S User Manual page 351

Layer 2 management switch
Table of Contents

Advertisement

Table 176 SNMP InterfaceTraps (continued)
OPTION
OBJECT LABEL
autonegotiation
zyPortAutonegotiationFailed
zyPortAutonegotiationFailedRec
overed
lldp
lldpRemTablesChange
transceiver-ddm
zyTransceiverDdmiTemperature
OutOfRange
zyTransceiverDdmiTxPowerOutO
fRange
zyTransceiverDdmiRxPowerOutO
fRange
zyTransceiverDdmiVoltageOutO
fRange
zyTransceiverDdmiTxBiasOutOfR
ange
zyTransceiverDdmiTemperature
OutOfRangeRecovered
zyTransceiverDdmiTxPowerOutO
fRangeRecovered
zyTransceiverDdmiRxPowerOutO
fRangeRecovered
zyTransceiverDdmiVoltageOutO
fRangeRecovered
zyTransceiverDdmiTxBiasOutOfR
angeRecovered
Chapter 42 Access Control
OBJECT ID
1.3.6.1.4.1.890.1.15.3.61.3.1
1.3.6.1.4.1.890.1.15.3.61.3.3
1.0.8802.1.1.2.0.0.1
1.3.6.1.4.1.890.1.15.3.84.3.1
1.3.6.1.4.1.890.1.15.3.84.3.2
1.3.6.1.4.1.890.1.15.3.84.3.3
1.3.6.1.4.1.890.1.15.3.84.3.4
1.3.6.1.4.1.890.1.15.3.84.3.5
1.3.6.1.4.1.890.1.15.3.84.3.6
1.3.6.1.4.1.890.1.15.3.84.3.7
1.3.6.1.4.1.890.1.15.3.84.3.8
1.3.6.1.4.1.890.1.15.3.84.3.9
1.3.6.1.4.1.890.1.15.3.84.3.10
MES3500-24S/MGS3520 Series User's Guide
351
DESCRIPTION
This trap is sent when an Ethernet
interface fails to auto-negotiate with
the peer Ethernet interface.
This trap is sent when an Ethernet
interface recovers from failing to
auto-negotiate with the peer Ethernet
interface.
The trap is sent when entries in the
remote database have any updates.
Link Layer Discovery Protocol (LLDP),
defined as IEEE 802.1ab, enables LAN
devices that support LLDP to
exchange their configured settings.
This helps eliminate configuration
mismatch issues.
This trap is sent when the transceiver
temperature is above or below the
normal operating range.
This trap is sent when the transmitted
optical power is above or below the
normal operating range.
This trap is sent when the received
optical power is above or below the
normal operating range.
This trap is sent when the transceiver
supply voltage is above or below the
normal operating range.
This trap is sent when the transmitter
laser bias current is above or below
the normal operating range.
This trap is sent when the transceiver
temperature is recovered from the
out of normal operating range.
This trap is sent when the transmitted
optical power is recovered from the
out of normal operating range.
This trap is sent when the received
optical power is recovered from the
out of normal operating range.
This trap is sent when the transceiver
supply voltage is recovered from the
out of normal operating range.
This trap is sent when the transmitter
laser bias current is recovered from
the out of normal operating range.

Advertisement

Table of Contents