3 PRODUCT DESCRIPTION
3.7

Technical data

3.7.1
General specifications
Typical deflection
Resolution XY2-100-E 16-Bit
Resolution SL2-100 20-Bit
Repeatability (RMS)
Max. Gain drift
Max. Offset drift
Long-term drift 8 h without water temperature
control
1
Long-term drift 8 h with water temperature
control
1, 2
IP-Code
Emission sound pressure level
Remark: All angles optical.
1) Drift per axis. After 30 min warm-up, at constant ambient temperature and process loads.
2) After 30 min warm-up, under varying process loads, with water temperature control set for ≥ 2 l/min and 22˚C water temperature.
3.7.2
Power supply
Voltage
Current
Ripple/ Noise
3.7.3
Control signals
Digital
Digital
3.7.4
Ambient conditions
Ambient temperature at operation
Storage temperature
Humidity
© 2022 RAYLASE GmbH SUPERSCAN IV
1
1
MN105-en / v1.0.12
±0.393 rad
12 μrad
0.76 μrad
< 2.0 μrad
15 ppm/K
10 μrad/K
< 60 μrad
< 40 μrad
64
< 70 dB(A)
+30 or +48 V
2 A, RMS, max. 5 A (< 10 ms)
Max. 200 mVpp, @ 20 MHz bandwidth
XY2-100-Enhanced protocol
SL2-100 protocol
+15 to +35 °C
-10 to +60 °C
≤ 80 % non-condensing
21