4 INSTALLATION
4.2

Installation location

The deflection unit may only be operated in closed rooms. It must be protected against contact with
liquids.
The deflection unit is not suitable for use in potentially explosive environment.
If the materials to be processed can result in toxic vapours, safe extraction of these must be ensured.
Other operating and ambient conditions must be observed (see page 21, Ambient conditions).
4.3

Preparing for installation

1. Make sure that the laser system is prepared in such a way that the laser beam is emitted centrally
and at a right angle from the installation surface for the deflection unit.
2. Prepare two aligning pins and four screws. The specifications for these can be found on the USB
stick supplied as part of the design data.
3. Carefully remove the deflection unit and any other accessories, for example the lens, from the
packaging.
4. Make sure that the specifications of the deflection unit and the lens correspond to the application
requirements (see page 21, Technical data and page 19, Signage).
In case of any variations, contact RAYLASE.
4.4

Installing the lens

1. Carefully remove the protective cover on the deflection unit beam output and the protective cover
Optional
on the lens.
2. Check the deflection unit and the lens for impurities and damage.
 Impurities must be removed before start-up (see page 38, Cleaning).
 Damaged components may not be used.
3. If a lens ring is included in the configuration, screw the lens ring into the deflection unit beam
output.
4. Carefully screw the lens into the deflection unit beam output.
4.5

Installing the protective window

1. Carefully remove the protective cover on the deflection unit beam output.
Optional
2. Carefully remove the protective window from the packaging. Only hold the protective window
with powder-free latex gloves and only by the edge, as fingerprints contain aggressive substances
that can damage the optical surfaces.
3. Check the deflection unit and the protective window for impurities and damage.
 Impurities must be removed before start-up (see page 38, Cleaning).
 Damaged components may not be used.
4. Install the protective window according to the figure in chapter Replacing the protective window,
page 40.
4.6

Installing the deflection unit

The installation of a SUPERSCAN IV with a RAYLASE Collimator Bracket Set for a fibre laser is done
according to chapter 4.6.2. A direct installation for example in combination with a solid-state laser is
done according to chapter 4.6.1.