Status Leds - RAYLASE SUPERSCAN IV-10 Manual

2-axis deflection units
Table of Contents

Advertisement

3 PRODUCT DESCRIPTION
3.5

Status LEDs

The status LEDs allow you to check important functions and statuses of the deflection unit. They are
located on top of the deflection unit.
The status LEDs are lettered. The first letter refers to the axis (XY) or the supply voltage (V) of the
deflection unit. The subsequent letters and their meaning is described below.
Fig. 9: LED XY
Name
... Par Err
... Err
... Dat
... OK
... Warn
... Inp OK
... Amp OK
© 2022 RAYLASE GmbH SUPERSCAN IV
Colour
Meaning
red
Parity Error
red
Error
yellow
Data Change
green
Operational
yellow
Warning
green
Power input
green
Power amplifier
MN105-en / v1.0.12
Flashes for each parity error. The flash duration is extended so
that even short-lived errors are visible.
On continuously if the clock or sync signals of the interface are
faulty.
On continuously to indicate a general fault on the axis, and also
during the boot sequence of the axis.The boot sequence lasts
for a few seconds.
As long as this LED is on, the output stage of the axis is disabled.
Flashes whenever data changes on the channel.The flash
duration is extended so that even short-lived changes are visible.
On continuously when the axis is ready for use.
Flashes whenever the axis is fully loaded. The flash duration is
extended so that even short-lived peak loads are visible.
On when the external supply voltage is applied and within the
required range.
On when the output stage is ready.