3.7.9.2
SL2-100 Interface
This interface can be used to connect the deflection unit to a RAYLASE control card. The detailed
information for the interface is set out below.
This interface is compatible to the SL2-100 protocol.
The SUPERSCAN IV's digital controller makes it possible to return data-signals to the control card. Data
are transferred every 10 µs to the controller card via the interface. There is one return channel for each
axis. This allows, for instance, monitoring the current axis positions during processing, or detailed
failure analysis following a malfunction.
Each axis also has a forward channel that can transfer a data packet to the scan head every 10 µs:
normally, these will be target positions for the axis.
Whenever it becomes necessary to transfer a command to the scan head during processing, e.g. to
change the type of information supplied on the return channel, the usual transmission of target
positions is suppressed for one 10 µs period. To avoid undesirable processing artefacts due to the
missing target position, a minimum interpolation period of 22 µs should be configured on the scan
head. The currently configured interpolation period can be retrieved via the command
Interpolation Configuration 0x0590
If the scan head's interpolation period is re-configured, it will also be necessary to adjust the laser-
delay settings to suit. The interpolation period has no effect on the dynamic behaviour of the scan
head.
All commands and the extensive capabilities of the SL2-100 interface are described in detail in the
SS-IV and SS-V Enhanced
manual
The signal pairs on PIN1/PIN6 and PIN5/PIN9 are each galvanically isolated by an internal transformer.
PIN2, PIN7 and PIN8 are intended only for supplying power to an optional external optical fiber
transmission unit. Noise immunity will be degraded if they are used for any other purpose, and they
should also not be connected to the identically named PINs on the controller card.
Fig. 11: D-SUB-9-F
PIN assignment
PIN
Signal
1
I
2
3
4
5
O
I = diff. input, nc = not connected, nu = not used, O = diff. output
© 2022 RAYLASE GmbH SUPERSCAN IV
, and set with the command
, which can be found on the supplied USB stick.
RS422_IN_iso+
VCC3V3
max. 200 mA
nc
nc
RS422_OUT_iso+
MN105-en / v1.0.12
SetMode
SetInterpolation 0x90
.
PIN
Signal
6
I
RS422_IN_iso-
7
GND
8
GND
9
O
RS422_OUT_iso-