RAYLASE SUPERSCAN IV-10 Manual page 29

2-axis deflection units
Table of Contents

Advertisement

3 PRODUCT DESCRIPTION
Specifications
RS422_IN...
Differential Input
Voltage
Differential Input
Termination (AC)
Differential Input
Impedance (DC)
Hysteresis
Data Cable
High quality screened twisted-pair cable of type 2-LifYCY 2x2x0.25 mm
connection. The wiring is shown below as viewed from the back of the D-SUB-9-M plugs:
Fig. 12: Wiring SL2-100 Interface
3.7.9.3
Power supply
The pin assignment of the power supply connector of the deflection unit is set out below. The housing
of the connector is connected to the housing of the deflection unit but not connected to GND.
Fig. 13: D-SUB-3W3-M
PIN assignment
PIN
Designation
1
Power GND
2
nc
3
VPOWER
nc = not connected
The details for the power supply are set out on page 21, Technical data.
© 2022 RAYLASE GmbH SUPERSCAN IV
RS422_OUT...
max. ±5 V
Differential Output
Voltage
Source Impedance
typ. 120 Ω
<1 Ω
typ. 30 mV
MN105-en / v1.0.12
typ. 2.5 Vpp
at 120 Ω load
typ. 120 Ω
2
must be used for the
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superscan iv-15Superscan iv-20Superscan iv-30

Table of Contents