Table 13. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
Error code
BA09000D
BA09000E
BA09000F
BA090010
Description
The media is unsupported or not
recognized.
The media is not formatted correctly.
Media is not present
The request sense command failed.
Action
1. Insert new media of the correct type.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Insert the media.
2. Insert new media of the correct type.
3. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Insert new media with the correct format.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Troubleshoot the SCSI devices.
2. Verify that the SCSI cables and devices are
properly plugged. Correct any problems
that are found.
3. Replace the SCSI cables and devices.
4. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
Chapter 2. Diagnostics
67