Table 24. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
A11-01x
A non-critical error has been detected, a
CPU internal error.
A11-02x
A non-critical error has been detected, a
CPU internal cache or cache controller
error.
A11-03x
A non-critical error has been detected,
an external cache parity or multi-bit
ECC error.
A11-05x
A non-critical error has been detected, a
system bus time-out error.
A11-06x
A non-critical error has been detected, a
time-out error waiting for an I/O
device.
A11-50x
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
A11-510
Resource has been deconfigured and is
no longer in use due to a trend toward
an unrecoverable error.
A11-540
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, see "Solving
undetermined problems" on page 231
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
1. If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2. Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
1. Schedule maintenance; the system is
operating in a degraded mode.
2. Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
1. If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2. Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
Chapter 2. Diagnostics
169