Table 13. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
Error code
BA340009
BA340010
BA340011
BA340020
BA340021
Description
An internal firmware error occurred; the
open fabric manager system initiator
capability processing encountered an
unexpected error.
An internal firmware error was detected
during open fabric manager processing.
Assignment of fabric ID to the I/O
adapter failed.
A logical partition event communication
failure occurred when writing the
BladeCenter open fabric manager
parameter data to the service processor.
A logical partition event communication
failure occurred when writing the
BladeCenter open fabric manager system
initiator capabilities data to the service
processor.
Action
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
Chapter 2. Diagnostics
87