IBM BladeCenter JS22 Problem Determination And Service Manual page 41

Table of Contents

Advertisement

Table 9. AA00E1A8 to AA260005 Partition firmware attention codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
Attention code
AA060011
AA130013
AA130014
AA170210
AA170211
AA190001
AA260001
AA260002
AA260003
AA260004
AA260005
Description
The firmware did not find an operating
system image and at least one hard disk
in the boot list was not detected by the
firmware. The firmware is retrying the
entries in the boot list.
Bootable media is missing from a USB
CD-ROM
The media in a USB CD-ROM has
changed.
Setenv/$setenv parameter error - the
name contains a null character.
Setenv/$setenv parameter error - the
value contains a null character.
The hypervisor function to get or set the
time-of-day clock reported an error.
Enter the Type Model Number (Must be
8 characters)
Enter the Serial Number (Must be 7
characters)
Enter System Unique ID (Must be 12
characters)
Enter WorldWide Port Number (Must be
12 characters)
Enter Brand (Must be 2 characters)
Action
This might occur if a disk enclosure that
contains the boot disk is not fully initialized or
if the boot disk belongs to another partition.
Verify that:
v The boot disk belongs to the partition from
which you are trying to boot.
v The boot list in the SMS menus is correct.
Verify that a bootable CD is properly inserted
in the CD or DVD drive and retry the boot
operation.
1. Retry the operation.
2. Check for server firmware updates; then,
install the updates if available and retry the
operation.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 270.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 270.
1. Use the operating system to set the system
clock.
2. If the problem persists, check for server
firmware updates.
3. Install any available updates and retry the
operation.
Enter the machine type and model of the blade
server at the prompt.
Enter the serial number of the blade server at
the prompt.
Enter the system unique ID number at the
prompt.
Enter the worldwide port number of the blade
server at the prompt.
Enter the brand number of the blade server at
the prompt.
Chapter 2. Diagnostics