Table 11. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
8144
Informational system log entry only.
8145
Informational system log entry only.
8150
System firmware detected an error.
8151
System firmware detected an error.
8152
No active system processors.
8160
A problem occurred during the
migration of a partition.
8161
A problem occurred during the
migration of a partition.
A100
A partition ended abnormally; the
partition could not stay running and
shut itself down.
A101
A partition ended abnormally; the
partition could not stay running and
shut itself down.
A140
A lower priority partition lost a
usable processor to supply it to a
higher priority partition with a bad
processor.
B07B
Informational system log entry only.
B215
A problem occurred after a partition
ended abnormally.
There was a communications
problem between this partition's
service processor and the platform's
service processor.
C1F0
An internal system firmware error
occurred during a partition
shutdown or a restart.
D150
A partition ended abnormally; there
was a communications problem
between this partition and the code
that handles resource allocation.
E0AA
A problem occurred during the
power off of a partition.
F001
A problem occurred during the
startup of a partition. An operation
has timed out.
38
JS22 Type 7998: Problem Determination and Service Guide
Action
No corrective action is required.
No corrective action is required.
Collect a platform dump and then go to "Isolating
firmware problems" on page 222.
Use the Integrated Virtual Manager (IVM) to increase the
Logical Memory Block (LMB) size, and to reduce the
number of virtual devices for the partition.
Verify that processor resources are assigned to the
partition.
Contact IBM support, as described in Appendix A,
"Getting help and technical assistance," on page 281.
Contact IBM support, as described in Appendix A,
"Getting help and technical assistance," on page 281.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to "Isolating firmware problems" on page 222.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to "Isolating firmware problems" on page 222.
Evaluate the entire LPAR configuration. Adjust partition
profiles with the new number of processors available in
the system.
No corrective action is required.
Restart the platform.
Go to "Isolating firmware problems" on page 222.
Check for server firmware updates; then, install the
updates if available.
Go to "Isolating firmware problems" on page 222.
Look for other errors and resolve them.