Scheduled Preventive Maintenance (To Be Done By A Specialised Technical Service Center) - Jolly Mec CULT 8 kW UP Instructions For Installation, Use And Maintenance Manual

Pellet operated air heating stove
Table of Contents

Advertisement

08.7

SCHEDULED PREVENTIVE MAINTENANCE (To be done by a specialised Technical Service Center)

We wish to remind you that the Extraordinary Maintenance to be carried out on this type of product must be done obligatorily every year
by qualified maintenance personnel, in order to maintain its functionality, efficiency and comfort.
For any further queries you may have, we invite you to contact the specialised Technical Service Center through your retailer. Scheduled
maintenance must include:
Cleaning of the flue (with special focus on horizontal segments)
Stove fume pass cleaning
Cleaning of any deposits in the stove
Cleaning of the flue-gas pipe inside the stove (if present)
Cleaning of fans
Check good ignition resistance operations
Check electric/electronic system integrity
Check safety device, thermostat and pressure switch status and efficiency
Check the condition of the sealing gaskets, paying special attention to the one on the closure of the combustion chamber
door.
Check the condition of the ceramic glass.
Check the pellet loading gear motor is working properly.
Clean the bottom of the pellet hopper.
WARNING
To carry out these operations, the appliance must be disconnected from the mains; wait until the appliance is
cold and comply rigorously with the safety regulations in force
- Opening side panels for maintenance.
To open the side panels proceed as follows:
a) unscrew the screws A, B, C (Fig. 1);
c) rotate the side panel (Fig. 2);
Remove the panel from the seat (pin E/seat e - pin D/seat d) (Fig. 3);
To reposition the panel follow the sequence in reverse.
The procedure also applies to the left side panel.
Fig. 1
A
B
C
Fig. 2
D
Fig. 3
d
e
E
33

Advertisement

Table of Contents
loading