CHAP.06 TECHNICAL DATA

06.1

HOMOLOGATION

Technical specifications resulting from laboratory tests conducted according to EN 14785:2006 test methods at the CERTIFICATION
institute.
Description
Nominal burning output
Nominal heat output
Reduced heat output
Nominal output consumption
Reduced output consumption
Nominal output efficiency
Rated voltage
Rated frequency
Electrical absorption
(Switching on - nominal power - reduced power - stand-by)
Device mass
Standard hopper capacity
Flue draught
Fume exhaust diam.
Average fume Temperature at nominal output
Average fume Temperature at reduced output
CO (13% O
) at nominal output
2
CO (13% O
) at reduced output
2
CO
at nominal output
2
NOx (13% O
) at nominal output
2
OGC (13% O
) at nominal output
2
Polveri (13% O
) at nominal output
2
Nominal fume mass output
Reduced fume mass output
Average heated area*
Minimum air distance from inflammable side wall
Minimum air distance from inflammable rear wall
Frontal air distance from inflammable material
Comburent air pipe diameter
Energy efficiency class
The declared output may vary according to fuel type.
The above technical specifications were measured with certified quality PELLETS. ONLY use this type of fuel as recommended later in
CHAP.06.2 - RECOMMENDED FUELS.
*According to the typology of building and insulation (Referred to the need of 55 W/m
WARNING
All appliance tests, final inspection and fine-tuning was performed using the recommended certified pellets. Jolly
Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of pellets that are not
recommended, as combustion parameters vary according to the quality of the pellets.
To achieve best operational results, it may be necessary to change the default factory settings on the control unit during
the optional Commissioning service. These operations must only be performed by a specialised Technical Service Center.
CULT 8 kW UP
UM
9,0
kW
kW
8,2
kW
2,9
Kg/h
1,88
0,62
Kg/h
91,1
%
230
V
Hz
50
W
325 - 54 - 25 - 2,3
Kg
99,2
Kg
15
10
Pa
mm
80
144,61
°C
°C
73,50
mg/m
136,6
3
mg/m
201,4
3
10,84
%
145,4
mg/m
3
mg/m
0,29
3
mg/m
14,26
3
g/s
5,98
g/s
2,54
55,2 - 86,7
m
2
150
mm
mm
100
mm
900
mm
50
A+
-
and 35 W/m
3
; room height 2,7 m).
3
15