Fig. 13
Fig. 15
Fig. 16
Fig. 18
Fig. 14
Fig. 17
Fig. 19
5.
Fume inspection cleaning
Remove the inspection cover under the ash pan and clean
carefully this space.
Use the ash vacuum spout to suction all the residual ash left at
the bottom of the exchanger entering the inspection hatch with
the ash vacuum handle (make sure residual ashes are cold)
(Fig. 13-14-15).
After cleaning, place the inspection cover as installed previously.
6.
Pellet tank opening for cleaning and loading
Apply light pressure to lift the pellet hopper cover, pulling
upwards, to release the magnet closure (Fig. 16-17).
Empty the pellet container every 500-1000 Kg of pellet burnt,
and check that no sawdust has accumulated on the bottom.
Clean the bottom of the container carefully.
After a long period of inactivity, empty the container and auger
completely.
Located on the rear part of the device, the hopper is filled
through an openable lid. The hopper must be filled with pellets
using a shove (not supplied) (Fig. 18-19) and not poured in
directly from the bag.