SAFETY THERMOSTAT WITH MANUAL RESET

A safety thermostat is installed on the device to protect against any overheating of fuel contained in the pellet hopper and cause the
device to switch off if the temperature sensor reaches limit values which correspond to the thermostat trigger setting.
To restore normal appliance operations following forced shutdown by a thermostat, proceed as follows:
Fig. 1
C
B
A
D
1. Wait until the appliance is completely cold (on average 20
minutes);
2. Unscrew the thermostat reset button lid on the back of the
appliance (see Fig. 1, positions B);
3. Press the button until you hear a CLICK;
4. Refit the hood;
5. Reset the alarm from the radio remote control by pressing
the ON/OFF button and waiting for the OFF message;
6. Start up again the appliance.
If the alarm persists, contact the specialised Technical Service
Center.
Socket unit (Fig. 1):
A. Electrical socket with bi-polar switch and fuse protection (see
CHAP.07.4 - ELECTRICAL CONNECTIONS)
B. Thermal safety thermostat
C. Emergency console
D. Room temperature probe