Appliance Start And Use - Jolly Mec CULT 8 kW UP Instructions For Installation, Use And Maintenance Manual

Pellet operated air heating stove
Table of Contents

Advertisement

08.3

APPLIANCE START AND USE

After professionally installing the room ventilation system, the fume exhaust system and electrical system according to the relevant
regulations, the specialised Technical Service Center can provide the optional Commissioning service.
After the installation of the appliance for the first starting, in order to use the device, fill the tank with high quality pellets as recommended
and perform the pellet pre-loading from LOAD PELLET menu (see manual SM116), set the desired temperature values and the output
set value (we recommend to select level 3) and to start the device with the power key (see manual SM116). The appliance will remain
in operation until the room probe or thermostat is satisfied.
Whilst operating, the device has a heating output according to one of the 5 levels of output set. The device remains in operating mode;
i.e. at the heat output level, until the set ambient temperature is exceeded by 0.5 °C. At this point it will switch to the ECO mode function.
The device will switch back to work mode when the ambient temperature decreases 1.0°C below the SET ambient temperature.
When operating, the fan speed for the hot air depends on the output levels; the higher the output level, the faster the air will be pumped
through the front grid. The hot air fan automatically starts functioning according to the temperature of the fumes.
With STAND-BY mode enabled, it is possible to switch off the device if the ambient temperature conditions are satisfied within the values
set for the Delta OFF temperature value. The Delta OFF, is the temperature differential between the SET ambient temperature and the
actual ambient temperature. Therefore if, for instance, the SET ambient temperature is 19°C, with an Delta OFF of 2°C and a switch-off
delay of 5', when the ambient temperature remains above 21°C for at least 5 minutes, the device will switch off. The device will remain
in STD-BY until the ambient temperature reaches 1°C of the SET ambient temperature which correspond to the automatic start-up value
of the stove. In this condition, the stove is not actually off but is waiting to turn back on if the above conditions are satisfied.
Set SET CHRONO – MENU to time operation start and stop. The crono can be quickly started by pressing Button 6 on the main display
screen. CHRONO and STAND-BY modes cannot be activated simultaneously. The CHRONO function should be considered as a timer
function, while STAND-BY is a temperature function.
In the event of alarms and/or manual pellet load from MENU LOAD PELLET, the message CLEAN BASKET is a warning to be sure not
to turn on the stove with previous operation combustion products and/or not burnt pellets in the firebox. To cancel the message, clean the
brazier and press and hold down Button ON/OFF for three seconds. Pellet loading from the LOAD PELLET menu must be used only if
the loading must be performed only if the auger is empty (before turning the device on), after a NO PELLET alarm, or after maintenance
or cleaning of the container, with its consequent emptying. Every time the manual pellet load mode is enabled from the LOAD PELLET
menu, the firebox MUST be emptied to create the correct conditions for the stove start-up phase.
The device can be switched off while operating with manual intervention by the user or by setting a SET CHRONO or can switch off if an
alarm is triggered following a device malfunction. In the second case follow the indications provided in CHAP. 09 - FAULT DIAGNOSIS
AND TROUBLESHOOTING.
WARNING
The device must only be used with the combustion chamber door closed.
The pellet hatch must be closed while the machine is running.
The stove starting MUST ALWAYS be performed with clean and empty firebox.
WARNING
The installation technician must attend the optional Commissioning service since system components may
require adjustments not pertinent to the specialised Technical Service Center at this time.
Any additional work or intervention of the specialised Technicat Service Center due to the failure to complete the above
adjustments during the optional Commitioning service are at the user's expense.
NOTE
We recommend activating STAND-BY mode when permitted by factory and/or use conditions. Frequent starts
and stops may cause appliance malfunctions, possible no start alarms and waste energy and fuel.