Jolly Mec AERJOLLY EVO Series Instructions For Installation, Use And Maintenance Manual

Jolly Mec AERJOLLY EVO Series Instructions For Installation, Use And Maintenance Manual

Advertisement

Quick Links

AERJOLLY
EVO
INSTALLATION, USE AND
MAINTENANCE MANUAL
To be kept by the purchaser
AERJOLLY EVO
AERJOLLY EVO Serie S
Wood operated air system product

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AERJOLLY EVO Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Jolly Mec AERJOLLY EVO Series

  • Page 1 AERJOLLY INSTALLATION, USE AND MAINTENANCE MANUAL To be kept by the purchaser AERJOLLY EVO AERJOLLY EVO Serie S Wood operated air system product...
  • Page 2 Dear Customer, thank you for having chosen to heat and save with a Jolly Mec product. Please carefully read and keep this sheet before using the equipment. This sheet provides necessary information and suggestions on how to correctly install, use, clean and maintain the product.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS CHAP.01 PREMISES........................... 4 01.1 WARNINGS ..............................4 01.2 SYMBOLOGY ............................... 5 01.3 APPLIED STANDARDS ..........................5 01.4 USE AND STORING OF THE INSTALLATION AND MAINTENANCE MANUAL ........6 01.5 MANUFACTURER LIABILITY AND WARRANTY CONDITIONS ..............6 CHAP.02 ACCIDENT PREVENTION / SAFETY REGULATIONS .............. 7 02.1 GENERAL CONSIDERATIONS ........................
  • Page 4: Chap.01 Premises

    CHAP.01 PREMISES 01.1 WARNINGS • Familiarity and compliance with the instructions given in this manual will ensure quick installation and correct use of the appliance. • Read the manual attentively before commencing installation, and be certain to follow the directions it contains, otherwise the war- ranty could be invalidated and the performance and safety of the appliance jeopardized. • The installation manual is an integral part of the product and must be given to the user. • It must be kept in a safe place and consulted carefully, as all of the warnings provide important information on safety during instal- lation, use and maintenance. • Incorrect installation of the appliance could cause damage and injury to people or animals, for which the manufacture cannot not be held liable. • Installation shall be performed by qualified operators in accordance with the regulations in force in the Country of installation. • The manufacturer declines any contractual or non-contractual liability for damages caused by errors in installation or use of the appliance or failure to follow the instructions contained in this manual. • All rights on the reproduction of this technical manual are owned by Jolly Mec Caminetti S.p.A. The descriptions and illustrations provided in the following publication are not binding. • reserves the right to make any modifications that may be deemed appropriate. • Jolly Mec Caminetti S.p.A This manual cannot be given to third parties for perusal without the written permission of • Jolly Mec Caminetti S.p.A • The technical directions for installation contained in this manual should be considered as basic requirements. Regulations in some countries may be more restrictive; in this instance, comply fully with the regulations prevailing in the country of installation (all laws and local bylaws must be observed when installing and using the appliance, including those referring to national and European standards).
  • Page 5: Symbology

    This point is particularly important. An important point regarding behaviour for preventing injury and damage to DANGER materials is expressed. 01.3 APPLIED STANDARDS All JOLLY MEC products are constructed according to the following directives: European construction products regulation. • EU 305/2011 Machines. •...
  • Page 6: Use And Storing Of The Installation And Maintenance Manual

    01.5 MANUFACTURER LIABILITY AND WARRANTY CONDITIONS Upon the delivery of this manual, Jolly Mec S.p.A. cannot be held liable, whether civil or criminal, for accidents due to partial or total non-compliance with the specifications herein contained. The manufacturer is especially held harmless from any liability in the following cases: •...
  • Page 7: Chap.02 Accident Prevention / Safety Regulations

    CHAP.02 ACCIDENT PREVENTION / SAFETY REGULATIONS 02.1 GENERAL CONSIDERATIONS • The manual refers to essential aspects of the directives, regulations and dispositions on using the machine, summarising its most significant points. • General legal regulations and mandatory rules regarding injury prevention and environmental protection must be observed.
  • Page 8: Safety Regulations For Extraordinary Maintenance And Installation

    • Keep the ventilation grids in the area the appliance is installed in clean conditions. • Do not burn any fuel except wood. • Check and periodically clean the fume exhaust pipe, from the appliance to the flue (Union). • It is strictly prohibited to start up the product with the combustion chamber door open or allow it to run with the glass broken •...
  • Page 9: Equipment For Operators And Maintenance Personnel

    RESIDUAL RISKS Though JOLLY MEC CAMINETTI S.p.A. does everything within its power to produce its systems with the greatest competence regarding safety and consulting all the directives, laws, and regulations available, there are still, if minor, some residual risks during the phases of: •...
  • Page 10: Chap.03 Handling And Transport

    CHAP.03 HANDLING AND TRANSPORT 03.1 RECEIVING GOODS The machine is delivered on a pallet, packed in a wooden cage with a cellophane hood. when receiving merchandise, check that: • all packaging is intact • all of the merchandise indicated on the delivery bill has actually been delivered •...
  • Page 11: Chap.04 Ecological Regulations

    CHAP.04 ECOLOGICAL REGULATIONS 04.1 DISPOSAL OF THE MACHINE Directive 2012/19/UE (waste electrical and electronic equipment - WEEE): information for users. The crossed-out wastebasket symbol on the appliance means that at the end of its useful lifespan, the product must be disposed of separately from ordinary household wastes. The user is responsible for delivering the appliance to an appropriate collection facility at the end of its useful lifespan. Appropriate separate collection to permit recycling, treatment and environmentally compatible disposal helps prevent negative impact on the environment and human health and promotes recycling of the materials making up the product.
  • Page 12 END-OF-LIFE DISPOSAL OF THE EQUIPMENT COMPONENTS ( REGULATION (EU) 2015/1185 - Annex II - par. 3 - a) - 3) ) INSTRUCTIONS FOR CORRECT PRODUCT DISPOSAL The owner is fully and exclusively liable for stove demolition and disposal according to laws in force in his/her country regarding safety, respect and protection of the environment. At the end of its useful life, the product must not be disposed of together with urban waste. It can be delivered to the appropriate differentiated collection centres set up by the municipal administrations, or to retailers that provide this service.
  • Page 13: Chap.05 Description

    CHAP.05 DESCRIPTION 05.1 PRODUCT PRESENTATION Jolly-Mec products are the result of over forty years experience in the wooden biomass combustion sector; they are designed and engineered to meet the increasing demands of today’s markets with high performance levels and savings enveloped in a modern design. The AERJOLLY EVO fireplaces are monoblock wood burning with intermittent kind of combustible charging modality;insert devices approved to EN13229 Standard requirements.
  • Page 14: Product Identification

    05.2 PRODUCT IDENTIFICATION It is COMPULSORY to indicate the product MODEL, the LOT number and SERIAL NUMBER in all communications with the Manufacturer. Identification numbers are printed on the adhesive plate located on the back of the device as illustrated on the right. Stove performance values measured during inspection tests according to the indicated reference and EC markings are also included on the plate.
  • Page 15: Chap.06 Technical Data

    All appliance tests, final inspection and fine-tuning was performed using the recommended fuels. Jolly Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of wood logs that are not recommended, as combustion parameters vary according to the quality of the fuel.
  • Page 16: Recommended Fuels

    06.2 RECOMMENDED FUELS • WOOD QUALITY WARNING WOOD QUALITY IS VERY IMPORTANT; PLEASE READ THIS SECTION CAREFULLY The characteristics of fuel wood for stoves and fireplaces are defined by quality classes A1 and A2 set forth by UNI EN ISO 17225-5 standard.
  • Page 17: Components

    06.3 COMPONENTS The fireplace is supplied in a wooden crate on a pallet, packaged with a cellophane cover, polystyrene and with the following components: • Assembly, use and maintenance manual • Control panel with electronic controller (1) • Cast-iron grille for wood burning (2) •...
  • Page 18: Chap.07 Positioning And Connections For The Installer

    CHAP.07 POSITIONING AND CONNECTIONS FOR THE INSTALLER 07.1 FLUE OR FUME EXHAUST SYSTEM The flue or fume exhaust system is a fundamental element for the proper functioning of the stove and must comply with the following general standards: UNI EN 1856-1 Fireplaces - Requirements for metal fireplaces - Products for fireplace systems UNI EN 1856-2 Fireplaces - Requirements for metal fireplaces - Internal ducts and metal exhaust pipes...
  • Page 19: Installation Room Ventilation

    For appliance that must reach exhaust outlets that are not coaxial with regard to the issue of the fumes from the machine, changes in direction must be made using an open elbow of 45° (Fig. 1). The use of counter slope elements is forbidden.The flue union must have a constant section and allow soot to be collected and swept away.
  • Page 20: Prearrangement For Connections And Air Inlets Of The Stove Positioned In Acorner

    07.3 PREARRANGEMENT FOR CONNECTIONS AND AIR INLETS OF THE STOVE POSITIONED IN A CORNER WARNING Electrical connections must be carried out by skilled personnel according to the regulations in force (2014/30/UE and 2014/35/UE). Combustion air intake ducting Centre line Outside air inlet 200x200 mm Ambient temperature or ambient thermostat probe Power supply 230 V 50 Hz Omnipolar switch...
  • Page 21: Prearrangement For Electrical Connections And Air Inlets With Wall Instal

    07.4 PREARRANGEMENT FOR ELECTRICAL CONNECTIONS AND AIR INLETS WITH WALL INSTALLA- TION WARNING Electrical connections must be carried out by skilled personnel according to the regulations in force (2014/30/UE and 2014/35/UE). Power supply 230 V 50 Hz Omnipolar switch Centre line Outside air inlet 200x200 mm Combustion air intake ducting All measurements are in mm.
  • Page 22 • Installing the cladding: PRECAUTIONS • Protection of domestic walls Installation of the fireplace near inflammable walls is only allowed if you maintain the distances indicated below, or if suitable protection is interposed. The surfaces such as the flooring, ceiling and walls of the home in the vicinity of the fireplace must be protected to prevent overheating.
  • Page 23: Example Of Installed And Clad Fireplace

    07.5 EXAMPLE OF INSTALLED AND CLAD FIREPLACE 1. Fume exhaust 2. Air recirculating grid 400x100 mm (100 mm from the ceiling) (MANDATORY) 3. Control panel 4. Door 5. Combustion air intake ducting (see par 07.3 or 07.4) 6. Air recirculating grid 400x100 mm (50 mm from the floor) (MANDATORY) 7.
  • Page 24: Example Of Hot Air Ducting (Only For Fireplace Version)

    07.6 EXAMPLE OF HOT AIR DUCTING (only for Fireplace version) To duct the air into other rooms, assembly the “T” or “Y” connection (optional), in addiction to connect the grilles on the lining. The air pipes must be taken to the rooms to be heated. The return of air to the fireplace room must be guaranteed from every room in which the hot air arrives, through openings under the doors or outlets, via the grille at the back of the fireplace.
  • Page 25: Control Unit Electrical Wiring Diagram

    07.7 CONTROL UNIT ELECTRICAL WIRING DIAGRAM WARNING Electrical connections must be carried out by skilled personnel according to the regulations in force (2014/30/UE and 2014/35/UE). NOTE The representation of the components is approximate, but they can change in terms of shape.
  • Page 26: Chap.08 Use And Maintenance For The User

    CHAP.08 USE AND MAINTENANCE FOR THE USER 08.1 CONTROL UNIT The Electronic Control Unit manages all functions of the device and is controlled through a display suitably designed to use the following main functions: • Fan speed in manual mode •...
  • Page 27 When the wood logs are almost burnt out, reload the fireplace again with a small amount of wood, leaving the ash pan open again When the wood has burnt out and there are still some charcoal, add the maximum quantity of wood, or the amount required.
  • Page 28 • INSTALLATION AND USE OF SMOKE DAMPER Step 1: Fit the damper, with the rod and regulating unit. The fume Fig. 1 damper must be assembled so that when the damper is in vertical (completely open), the dial is horizontal (with the index on the right) Shutter and also the position indicator (IIII position) and it can be easily removed to clean the flue by extracting the rod (see Fig. 1)
  • Page 29: Tips And Warnings For The User

    08.3 TIPS AND WARNINGS FOR THE USER It is compulsory to clean the air exchange fan at least once a year. The water for the humidifier (max. capacity 3 litres) must be added manually through the filling pipe, which can be positioned on the left or right of the fireplace (the humidifier is full when the water reaches the level).
  • Page 30: Ordinary Maintenance (By The Costumer)

    08.4 ORDINARY MAINTENANCE (by the costumer) WARNING Before starting any type of cleaning, switch off the main switch and make sure that the appliance is cold. Never restart the stove before completing these operations and correctly reassembling all components. Cleaning tools supplied Flue brush Small brush Poker...
  • Page 31 Cleaning of the fume deflector Fig. 4 Fig. 5 Every 20 days, or even more frequently according to the type of fuel used, the flue chimney draught and the weather conditions, it is compulsory to remove the upper diffuser and clean it to prevent the fume outlet from clogging, causing the fumes to flow back into the room.
  • Page 32 Cleaning the glass Clean the glass daily with a damp sponge or paper hand towels. Be careful not to use overly aggressive products to avoid ruining the paint. Never spray detergents directly onto the parts to be cleaned. If the fireplace requires more frequent cleaning, check the flue draught and make sure the smoke baffle is clean (the minimum draught must be 12 Pascal;...
  • Page 33: Scheduled Preventive Maintenance (To Be Done By A Specialised Technical Service Center)

    08.5 SCHEDULED PREVENTIVE MAINTENANCE (To be done by a specialised Technical Service Center) WARNING To carry out these operations, the appliance must be disconnected from the mains; wait until the appliance is cold and comply rigorously with the safety regulations in force. We wish to remind you that the Extraordinary Maintenance to be carried out on this type of product must be done obligatorily every year by qualified maintenance personnel, in order to maintain its functionality, efficiency and comfort.
  • Page 34: Chap.09 Fault Diagnosis And Troubleshooting

    CHAP.09 FAULT DIAGNOSIS AND TROUBLESHOOTING 09.1 PROBLEMS WARNING In accordance with the laws in force on safety for electrical appliances, a specialised Technical Service Center or qualified personnel must obligatorily be contacted for all installation, maintenance or interventions that require access to electrical parts.
  • Page 35: Chap.10 Annexes

    COMMISSION REGULATION (EU) 2015/1185 Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Aerjolly EVO 7,5 kW Indirect heating functionality Direct heat output Indirect heat output...
  • Page 36 Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,120 Single stage heat output, no room At nominal heat output temperature control 0,120 Two or more manual stages, no At minimum heat room temperature control output 0,004...
  • Page 37 Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Aerjolly EVO 11 kW Indirect heating functionality Direct heat output 11,0 Indirect heat output Reference standard EN13229 Notified Body TÜV Rheinland Energy GmBH - NB 2456 - Am Grauen...
  • Page 38 Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,120 Single stage heat output, no room At nominal heat output temperature control 0,120 Two or more manual stages, no At minimum heat room temperature control output 0,004...
  • Page 39 Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Aerjolly EVO 12 kW Indirect heating functionality Direct heat output 12,1 Indirect heat output Reference standard EN13229 Notified Body TÜV Rheinland Energy GmBH - NB 2456 - Am Grauen...
  • Page 40 Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,120 Single stage heat output, no room At nominal heat output temperature control 0,120 Two or more manual stages, no At minimum heat room temperature control output 0,004...
  • Page 41 Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) RFE Aria L 7,5 kW Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body TÜV Rheinland Energy GmBH - NB 2456 - Am Grauen...
  • Page 42 Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,072 Single stage heat output, no room At nominal heat output temperature control 0,072 Two or more manual stages, no At minimum heat room temperature control output 0,008...
  • Page 43 Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) RFE Aria L 11 kW Indirect heating functionality Direct heat output 11,0 Indirect heat output Reference standard...
  • Page 44 Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,072 Single stage heat output, no room At nominal heat output temperature control 0,072 Two or more manual stages, no At minimum heat room temperature control output 0,008...
  • Page 45 Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) RFE Aria L 12 kW Indirect heating functionality Direct heat output 12,1 Indirect heat output Reference standard...
  • Page 46 Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,072 Single stage heat output, no room At nominal heat output temperature control 0,072 Two or more manual stages, no At minimum heat room temperature control output 0,008...
  • Page 47 NOTES...
  • Page 48 Via S.Giuseppe 2 - 24060 Telgate (Bg) Italy Tel. +39 035.83.59.211 Fax +39 035.83.59.203 www.jolly-mec.it - info@jolly-mec.it...

This manual is also suitable for:

Aerjolly evo s seriesRfe aria l series

Table of Contents