07.6
CONTROL UNIT ELECTRICAL WIRING DIAGRAM
WARNING
Electrical connections must be carried out by skilled personnel according to the regulations in force (2014/30/UE
and 2014/35/UE).
14
2
13
Number
1
Radio control
2
Electronic card
3
Bipolar switch
4
Electric power cord with schuko socket
5
Smoke fan
6
Electrical heating element
7
Exchange fan
8
Bulb type safety thermostat
9
Fume pressure switch
10
Pellet loader gear motor
NOTE
The representation of the components is approximate, but they can change in terms of shape.
24
18
3
19
11
Description
4
5
12
15
6
9
8
17
1
16
Number
11
Ambient probe
12
Smoke probe
13
Pressure sensor for the air setting inlet
14
Emergency control console / radio antenna for radio
remote control
15
Electrical capacitor for fume extractor fan
16
Encoder Screw
17
Hot air exchange fan condenser
1
7
Description