2.3.6. Brake Outputs

The drive has a dedicated brake control circuit. Configure the brake with the BrakeSetup
[A3200: EnableBrakeControl] parameter for automatic control (typical). You can also use software
commands to directly control the brake output.
Refer to
Section 2.6.
Table 2-23:
Brake Output Pins on the Feedback Connector
Pin #
Description
13
Brake Output -
25
Brake Output + 
Table 2-24:
Brake Control Specifications
Specification
Maximum Voltage
Maximum Current
A varistor must be connected across the brake to minimize voltage transients.
Figure 2-32:
Brake Connected to the 25-Pin Feedback Connector (Typical)
www.aerotech.com
for more information on powering the brake circuit.
In/Out/Bi
Output
Output
Value
24 VDC
1 A
iXC4/XC4