Mechanical Specifications; Mounting And Cooling; Table 1-4: Mounting Specifications - Advantech Automation1 iXC4 Hardware Manual

Pwm digital drives
Table of Contents

Advertisement

Hardware Manual

1.2. Mechanical Specifications

1.2.1. Mounting and Cooling

The drive must be installed in an enclosed control cabinet suitable for installation of power
equipment. A minimum enclosure rating of IP54 is required to comply with safety standards. Make
sure that there is sufficient clearance surrounding the drive for free airflow and for the routing of
cables and connections. Consideration for items such as line reactors, line filters, and motor chokes
or inductance should be made during the initial cabinet design phase.
IMPORTANT: The amount of airflow required to keep the drive temperature within a
sufficient range is dependent on the operating conditions. You could be required to
supply additional airflow to the drive.
Table 1-4:
Mounting Specifications
Customer-Supplied Enclosure
Weight
Mounting Hardware
Mounting Orientation
Dimensions
Minimum Clearance
Operating Temperature
Drive IP Rating
www.aerotech.com
M4 [#8] screws (four locations, not included)
Airflow
Connectors
Refer to
iXC4/XC4
IP54 Compliant
2.4 kg
Vertical (typical)
Section 1.2.2. Dimensions
Refer to
~25 mm
~100 mm
Section 1.3. Environmental Specifications
IP20
iXC4/XC4
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Automation1 xc4

Table of Contents