2.3.5. End of Travel and Home Limit Inputs

End of Travel (EOT) limits are required to define the end of the physical travel on linear axes. Positive
or clockwise motion is stopped by the clockwise (CW) end of travel limit input. Negative or
counterclockwise motion is stopped by the counterclockwise (CCW) end of travel limit input. The
Home Limit switch can be parameter configured for use during the home cycle, however, the CW or
CCW EOT limit is typically used instead. All of the end-of-travel limit inputs accept 0-24 VDC level
signals. Limit directions are relative to the encoder polarity in the diagnostics display (refer to
2-31).
Table 2-22:
End of Travel and Home Limit Pins on the Feedback Connector
Pin #
Description
12
Clockwise End of Travel Limit
16
+5V Power
20
Signal Common
21
Signal Common
22
Home Switch Input
24
Counterclockwise End of Travel Limit
The active state (High/Low) of the EOT limits is software selectable (by the EndOfTravelLimitSetup
axis parameter).
normally-closed switches and the parameter setting to use for each configuration.
IMPORTANT: Use NPN-type normally-closed limit switches (Active High) to provide fail-
safe behavior in the event of an open circuit.
54
Figure 2-29
shows the possible wiring configurations for normally-open and
Hardware Manual
Figure
In/Out/Bi
Input
Output
Output
Output
Input
Input
www.aerotech.com